Electron beam-irradiated donor cornea for on-demand lenticule implantation to treat corneal diseases and refractive error
Acta Biomaterialia · 2023
DOI: 10.1016/j.actbio.2023.07.053 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Biomaterialia, 2023. Verfasst von Arun J Thirunavukarasu und 10 weiteren Autor:innen. Beteiligte Einrichtung: Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore; University of Cambridge School of Clinical Medicine, Cambridg…. Hauptthemen laut MEDLINE: Corneal Surgery, Laser, Refractive Errors, Keratoconus. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: Lee Foundation, National Medical Research Council.
Abstract (Originalsprache)
The cornea is the major contributor to the refractive power of the eye, and corneal diseases are a leading cause of reversible blindness. The main treatment for advanced corneal disease is keratoplasty: allograft transplantation of the cornea. Examples include lenticule implantation to treat corneal disorders (e.g. keratoconus) or correct refractive errors. These procedures are limited by the shelf-life of the corneal tissue, which must be discarded within 2-4 weeks. Electron-beam irradiation is an emerging sterilisation technique, which extends this shelf life to 2 years. Here, we produced lenticules from fresh and electron-beam (E-beam) irradiated corneas to establish a new source of tissue for lenticule implantation. In vitro, in vivo, and ex vivo experiments were conducted to compare fresh and E-beam-irradiated lenticules. Results were similar in terms of cutting accuracy, ultrastructure, optical transparency, ease of extraction and transplantation, resilience to mechanical handling, biocompatibility, and post-transplant wound healing process. Two main differences were noted. First, ∼59% reduction of glycosaminoglycans resulted in greater compression of E-beam-irradiated lenticules post-transplant, likely due to reduced corneal hydration-this appeared to affect keratometry after implantation. Cutting a thicker lenticule would be required to ameliorate the difference in refraction. Second, E-beam-sterilised lenticules exhibited lower Young's modulus which may indicate greater care with handling, although no damage or perforation was caused in our procedures. In summary, E-beam-irradiated corneas are a viable source of tissue for stromal lenticules, and may facilitate on-demand lenticule implantation to treat a wide range of corneal diseases. Our study suggested that its applications in human patients are warranted. STATEMENT OF SIGNIFICANCE: Corneal blindness affects over six million patients worldwide. For patients requiring corneal transplantation, current cadaver-based procedures are limited by the short shelf-life of donor tissue. Electron-beam (E-beam) sterilisation extends this shelf-life from weeks to years but there are few published studies of its use. We demonstrated that E-beam-irradiated corneas are a viable source of lenticules for implantation. We conducted in vitro, in vivo, and ex vivo comparisons of E-beam and fresh corneal lenticules. The only differences exhibited by E-beam-treated lenticules were reduced expression of glycosaminoglycans, resulting in greater tissue compression and lower refraction suggesting that a thicker cut is required to achieve the same optical and refractive outcome; and lower Young's modulus indicating extra care with handling.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore; University of Cambridge School of Clinical Medicine, Cambridge, United Kingdom.
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore.
- School of Materials Science and Engineering, Nanyang Technological University, Singapore.
- Lions World Vision Institute, Tampa, FL, USA.
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore; Singapore National Eye Centre, Singapore; Ophthalmology and Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, S…
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore; Singapore National Eye Centre, Singapore.
Förderung
- Lee Foundation
- National Medical Research Council
Zitieren
APA
Thirunavukarasu, A. J., Han, E., Nedumaran, A. M., Kurz, A. C., Shuman, J., Yusoff, N. Z. B. M., Liu, Y. C., Foo, V., Czarny, B., Riau, A. K., & Mehta, J. S. (2023). Electron beam-irradiated donor cornea for on-demand lenticule implantation to treat corneal diseases and refractive error. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2023.07.053
Vancouver
Thirunavukarasu AJ, Han E, Nedumaran AM, Kurz AC, Shuman J, Yusoff NZBM, et al. Electron beam-irradiated donor cornea for on-demand lenticule implantation to treat corneal diseases and refractive error. Acta Biomaterialia. 2023. doi:10.1016/j.actbio.2023.07.053
BibTeX
@article{Thirunavukarasu2023,
author = {Thirunavukarasu, Arun J and Han, Evelina and Nedumaran, Anu Maashaa and Kurz, Arthur C and Shuman, Jeremy and Yusoff, Nur Zahirah Binte M and Liu, Yu-Chi and Foo, Valencia and Czarny, Bertrand and Riau, Andri K and Mehta, Jodhbir S},
title = {Electron beam-irradiated donor cornea for on-demand lenticule implantation to treat corneal diseases and refractive error},
journal = {Acta Biomaterialia},
year = {2023},
doi = {10.1016/j.actbio.2023.07.053}
}
EUVIMED