EUVIMEDEUVIMED entdecken
Open Access

Comparative study of small incision refractive lenticule extraction with 5 mm versus 6.5 mm optic zone for myopia

Jeevan S Ladi, Anita Gaikwad, Nitant A Shah

Indian Journal of Ophthalmology · 2023

DOI: 10.4103/ijo.ijo_2559_22 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, 2023. Verfasst von Jeevan S Ladi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Dada Laser Eye Institute, Pune, Maharashtra, India. Hauptthemen laut MEDLINE: Myopia, Refractive Errors, Corneal Surgery, Laser. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare residual stromal thickness (RST) in eyes undergoing small incision refractive lenticule extraction (SMILE) using a lenticular diameter of 6.5 mm versus those with a diameter of 5 mm.

Methods

In this retrospective comparative case series, consecutive patients who underwent SMILE between 2016 and 2021 with at least 6 months of follow-up were included. Preoperative best-corrected distance visual acuity (BCDVA), refractive error, contrast sensitivity, central corneal thickness, keratometry, higher order aberrations, and scotopic pupil size were recorded using a Placido disk topography with Sheimpflug tomography-based system. Patients underwent SMILE with a lenticular diameter of 6.5 mm until 2018 ( n = 372 eyes). Thereafter, the lenticular diameter was reduced to 5 mm ( n = 318). The RST, postoperative refraction, aberrations, subjective glare, and halos were compared across groups at 1 and 6 months.

Results

The mean age of participants was 26.8 ± 5.8 years with a mean preoperative spherical equivalent of −4.48 D ± 2.16 D (range: −0.75 to −12.25 D) and mean scotopic pupil of 3.7 ± 0.75 mm. Eyes in the 5 mm group had 30.6 m (95% confidence interval [CI] = 28 to 33 m, P < 0.001) greater RST compared to the 6.5 mm group after adjusting for spherical equivalent and preoperative pachymetry. There were no differences in vision, contrast sensitivity, aberrations (wavefront error of 0.19 ± 0.2 vs. 0.25 ± 0.2, P = 0.19) or glare between the two groups.

Conclusion

SMILE performed with a lenticular diameter of 5 mm leads to greater RST across the myopic range, but without inducing significant higher-order aberrations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MyopiaRefractive ErrorsCorneal Surgery, LaserHumansYoung AdultAdultVisual AcuityRetrospective StudiesRefraction, OcularLasers, ExcimerCorneal Stroma

Stichwörter der Autor:innen

5 mm optic zoneReLEx-SMILEmyopiaresidual stromal thickness

Autor:innen und Institutionen

  • Department of Ophthalmology, Dada Laser Eye Institute, Pune, Maharashtra, India.

Zitieren

APA

Ladi, J. S., Gaikwad, A., & Shah, N. A. (2023). Comparative study of small incision refractive lenticule extraction with 5 mm versus 6.5 mm optic zone for myopia. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_2559_22

Vancouver

Ladi JS, Gaikwad A, Shah NA. Comparative study of small incision refractive lenticule extraction with 5 mm versus 6.5 mm optic zone for myopia. Indian Journal of Ophthalmology. 2023. doi:10.4103/ijo.ijo_2559_22

BibTeX
@article{Ladi2023,
  author = {Ladi, Jeevan S and Gaikwad, Anita and Shah, Nitant A},
  title = {Comparative study of small incision refractive lenticule extraction with 5 mm versus 6.5 mm optic zone for myopia},
  journal = {Indian Journal of Ophthalmology},
  year = {2023},
  doi = {10.4103/ijo.ijo_2559_22}
}
Kostenlos starten →