EUVIMEDEUVIMED entdecken
Open Access

Reducing the foreign body response on human cochlear implants and their materials in vivo with photografted zwitterionic hydrogel coatings

Ryan Horne, Nir Ben-Shlomo, Megan Jensen, Morgan Ellerman, Caleb Escudero, Rong Hua, Douglas Bennion, C Allan Guymon, Marlan R Hansen

Acta Biomaterialia · 2023

DOI: 10.1016/j.actbio.2023.05.011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Biomaterialia, 2023. Verfasst von Ryan Horne und 8 weiteren Autor:innen. Beteiligte Einrichtung: University of Iowa Carver College of Medicine, United States of America; University of Iowa Department of Chemical and Biochemical Engineering, Unite…. Hauptthemen laut MEDLINE: Cochlear Implants, Foreign Bodies. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCATS NIH HHS, NIGMS NIH HHS, NIDCD NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The foreign body response to implanted materials often complicates the functionality of sensitive biomedical devices. For cochlear implants, this response can reduce device performance, battery life and preservation of residual acoustic hearing. As a permanent and passive solution to the foreign body response, this work investigates ultra-low-fouling poly(carboxybetaine methacrylate) (pCBMA) thin film hydrogels that are simultaneously photo-grafted and photo-polymerized onto polydimethylsiloxane (PDMS). The cellular anti-fouling properties of these coatings are robustly maintained even after six-months subcutaneous incubation and over a broad range of cross-linker compositions. On pCBMA-coated PDMS sheets implanted subcutaneously, capsule thickness and inflammation are reduced significantly in comparison to uncoated PDMS or coatings of polymerized poly(ethylene glycol dimethacrylate) (pPEGDMA). Further, capsule thickness is reduced over a wide range of pCBMA cross-linker compositions. On cochlear implant electrode arrays implanted subcutaneously for one year, the coating bridges over the exposed platinum electrodes and dramatically reduces the capsule thickness over the entire implant. Coated cochlear implant electrode arrays could therefore lead to persistent improved performance and reduced risk of residual hearing loss. More generally, the in vivo anti-fibrotic properties of pCBMA coatings also demonstrate potential to mitigate the fibrotic response on a variety of sensing/stimulating implants. STATEMENT OF SIGNIFICANCE: This article presents, for the first time, evidence of the in vivo anti-fibrotic effect of zwitterionic hydrogel thin films photografted to polydimethylsiloxane (PDMS) and human cochlear implant arrays. The hydrogel coating shows no evidence of degradation or loss of function after long-term implantation. The coating process enables full coverage of the electrode array. The coating reduces fibrotic capsule thickness 50-70% over a broad range of cross-link densities for implantations from six weeks to one year.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cochlear ImplantsForeign BodiesHumansHydrogelsCoated Materials, BiocompatibleDimethylpolysiloxanes

Stichwörter der Autor:innen

Anti-foulingCochlear implantsFibrotic capsule thicknessForeign body responseZwitterionic hydrogels

Substanzen

HydrogelsCoated Materials, BiocompatibleDimethylpolysiloxanes

Autor:innen und Institutionen

  • University of Iowa Carver College of Medicine, United States of America; University of Iowa Department of Chemical and Biochemical Engineering, United States of America.
  • University of Iowa Hospitals and Clinics Department of Otolaryngology, United States of America.
  • University of Iowa Department of Chemical and Biochemical Engineering, United States of America.
  • University of Iowa Carver College of Medicine, United States of America.
  • University of Iowa Hospitals and Clinics Department of Otolaryngology, United States of America. Electronic address: marlan-hansen@uiowa.edu.

Förderung

  • NCATS NIH HHS
  • NIGMS NIH HHS
  • NIDCD NIH HHS
  • National Institutes of Health
  • NIDCD

Zitieren

APA

Horne, R., Ben-Shlomo, N., Jensen, M., Ellerman, M., Escudero, C., Hua, R., Bennion, D., Guymon, C. A., & Hansen, M. R. (2023). Reducing the foreign body response on human cochlear implants and their materials in vivo with photografted zwitterionic hydrogel coatings. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2023.05.011

Vancouver

Horne R, Ben-Shlomo N, Jensen M, Ellerman M, Escudero C, Hua R, et al. Reducing the foreign body response on human cochlear implants and their materials in vivo with photografted zwitterionic hydrogel coatings. Acta Biomaterialia. 2023. doi:10.1016/j.actbio.2023.05.011

BibTeX
@article{Horne2023,
  author = {Horne, Ryan and Ben-Shlomo, Nir and Jensen, Megan and Ellerman, Morgan and Escudero, Caleb and Hua, Rong and Bennion, Douglas and Guymon, C Allan and Hansen, Marlan R},
  title = {Reducing the foreign body response on human cochlear implants and their materials in vivo with photografted zwitterionic hydrogel coatings},
  journal = {Acta Biomaterialia},
  year = {2023},
  doi = {10.1016/j.actbio.2023.05.011}
}
Kostenlos starten →