EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Single-Phase Surrogate for True Non-Contrast Liver CT Using 190-keV Monoenergetic Imaging on Photon-Counting CT: Implications for Hepatic Steatosis Assessment

Takashi Ohtani, Masato Shimada, Kaede Nishiyama, Hiroki Shimoyama, Midori Ueda, Sayuri Hakoda, Yukihiro Tomita, Kenji Takata, Toshiki Tateishi, Tetsuya Tsujikawa

Academic Radiology · 2026-10 · 33 (10) · 4265-4275

DOI: 10.1016/j.acra.2026.06.064 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2026-10. Verfasst von Takashi Ohtani und 9 weiteren Autor:innen. Beteiligte Einrichtung: Radiological Center, University of Fukui Hospital, Japan (T.O., M.S., K.N., T.T.). Electronic address: ohtanita@u-fukui.ac.jp. Hauptthemen laut MEDLINE: Fatty Liver, Tomography, X-Ray Computed, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: University of Fukui.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: To evaluate whether 190-keV virtual monoenergetic imaging (VMI) using photon-counting detector CT (PCD-CT) can serve as a surrogate for true non-contrast (TNC) in hepatic steatosis quantification and to compare its attenuation agreement with virtual non-contrast (VNC). METHODS: Forty-nine patients who underwent abdominal PCD-CT and MRI-proton density fat fraction (PDFF) within 2 months were retrospectively analyzed. VNC and 190-keV VMI were reconstructed from equilibrium-phase scans. Liver attenuation was measured on TNC, VNC, and 190-keV VMI in four hepatic segments. Pearson correlation and Bland-Altman analyses assessed agreement with TNC. Receiver operating characteristic analysis evaluated diagnostic performance for steatosis (MRI-PDFF ≥ 5%). Statistical analyses were performed using MedCalc (version 23.4) and GraphPad Prism (version 10.6.1). Statistical significance was defined as p < 0.05. RESULTS: The study included 49 patients (30 men, 19 women; mean age, 66.7 ± 11.2 years). In whole-liver analysis, 190-keV VMI correlated strongly with TNC (r=0.921, p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fatty LiverTomography, X-Ray ComputedRadiographic Image Interpretation, Computer-AssistedHumansFemaleMaleAgedSensitivity and SpecificityReproducibility of ResultsMiddle AgedRetrospective StudiesPhotonsRadiographic Image Enhancement

Stichwörter der Autor:innen

Hepatic steatosisPhoton-counting CTVirtual monoenergetic imagingVirtual non-contrast

Autor:innen und Institutionen

  • Radiological Center, University of Fukui Hospital, Japan (T.O., M.S., K.N., T.T.). Electronic address: ohtanita@u-fukui.ac.jp.
  • Radiological Center, University of Fukui Hospital, Japan (T.O., M.S., K.N., T.T.). Electronic address: mshima@u-fukui.ac.jp.
  • Radiological Center, University of Fukui Hospital, Japan (T.O., M.S., K.N., T.T.). Electronic address: kaenishi@u-fukui.ac.jp.
  • Department of Radiology, Faculty of Medical Sciences, University of Fukui, Japan (H.S., M.U., S.H., Y.T., K.T., T.T.). Electronic address: shimo@u-fukui.ac.jp.
  • Department of Radiology, Faculty of Medical Sciences, University of Fukui, Japan (H.S., M.U., S.H., Y.T., K.T., T.T.). Electronic address: mido130286@gmail.com.
  • Department of Radiology, Faculty of Medical Sciences, University of Fukui, Japan (H.S., M.U., S.H., Y.T., K.T., T.T.). Electronic address: ws234yki98zsxut1713r@gmail.com.

Förderung

  • University of Fukui

Zitieren

APA

Ohtani, T., Shimada, M., Nishiyama, K., Shimoyama, H., Ueda, M., Hakoda, S., Tomita, Y., Takata, K., Tateishi, T., & Tsujikawa, T. (2026). Single-Phase Surrogate for True Non-Contrast Liver CT Using 190-keV Monoenergetic Imaging on Photon-Counting CT: Implications for Hepatic Steatosis Assessment. Academic Radiology, 33(10), 4265-4275. https://doi.org/10.1016/j.acra.2026.06.064

Vancouver

Ohtani T, Shimada M, Nishiyama K, Shimoyama H, Ueda M, Hakoda S, et al. Single-Phase Surrogate for True Non-Contrast Liver CT Using 190-keV Monoenergetic Imaging on Photon-Counting CT: Implications for Hepatic Steatosis Assessment. Academic Radiology. 2026;33(10):4265-4275. doi:10.1016/j.acra.2026.06.064

BibTeX
@article{Ohtani2026,
  author = {Ohtani, Takashi and Shimada, Masato and Nishiyama, Kaede and Shimoyama, Hiroki and Ueda, Midori and Hakoda, Sayuri and Tomita, Yukihiro and Takata, Kenji and Tateishi, Toshiki and Tsujikawa, Tetsuya},
  title = {Single-Phase Surrogate for True Non-Contrast Liver CT Using 190-keV Monoenergetic Imaging on Photon-Counting CT: Implications for Hepatic Steatosis Assessment},
  journal = {Academic Radiology},
  year = {2026},
  volume = {33},
  number = {10},
  pages = {4265--4275},
  doi = {10.1016/j.acra.2026.06.064}
}
Kostenlos starten →