EUVIMEDEUVIMED entdecken
Vergleichsstudie

The value of Ultrasound Fat Fraction as compared to Controlled Attenuation Parameter for the severity of liver steatosis assessment - preliminary results

Camelia Nica, Ioan Sporea, Alexandru Popa, Raluca Lupușoru, Maria Voicu Stan Erimescu, Roxana Șirli, Mirela Dănilă, Daiana Boleac, Ariadna Plesa, Alina Popescu

Medical Ultrasonography · 2026

DOI: 10.11152/mu-4575 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Medical Ultrasonography, 2026. Verfasst von Camelia Nica und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine II, Division of Gastroenterology and Hepatology, Advanced Regional Research Center in Gastroenterology and Hepatology…. Hauptthemen laut MEDLINE: Fatty Liver. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

Liver steatosis is a growing global health concern with significant medical and economic implications. This study aimed to evaluate USFF (ultrasound fat fraction) for steatosis assessment as compared to controlled attenuation parameter (CAP).Materials and methods: Liver steatosis was assessed in the same session by QUS (Samsung Medison RS85) and CAP (FibroScan Compact M530) in a cohort of 169 patients. For QUS, TAI and TSI measurements were acquired, then Fat Fraction (%) was calculated and displayed. The CAP cut-off values for S1, S2 and S3 were 248, 268 and 280 dB/m, respectively. ROC analysis was performed to identify the best cut-off values for USFF for each steatosis stage.

Results

Of the 169 patients, 52.6% had at least moderate steatosis by CAP. Moderate correlations were observed for TSI vs. CAP (r=0.66), TAI vs. CAP (r=0.83), and TSI vs. TAI (r=0.68), with good diagnostic performance (TSI AUROC=0.82, TAI AUROC=0.81). A strong correlation between USFF and CAP was also found (r=0.81, p5% with very good performance (AUROC=0.90) for moderate steatosis the cut-off value was >7.5% (AUROC=0.92) and for severe steatosis, >10% (AUROC=0.91).

Conclusion

USFF seems to be a promising tool for diagnosing liver steatosis, with a very good performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fatty LiverHumansFemaleMaleSeverity of Illness IndexUltrasonographyMiddle AgedReproducibility of ResultsSensitivity and SpecificityLiverAdultAgedAdipose Tissue

Autor:innen und Institutionen

  • Department of Internal Medicine II, Division of Gastroenterology and Hepatology, Advanced Regional Research Center in Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, Timisoara.
  • Department of Internal Medicine II, Division of Gastroenterology and Hepatology, Advanced Regional Research Center in Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, Timisoara. popa.…
  • Center for Modeling Biological Systems and Data Analysis, Department of Functional Sciences, "Victor Babes" University of Medicine and Pharmacy, Timisoara.

Zitieren

APA

Nica, C., Sporea, I., Popa, A., Lupușoru, R., Voicu Stan Erimescu, M., Șirli, R., Dănilă, M., Boleac, D., Plesa, A., & Popescu, A. (2026). The value of Ultrasound Fat Fraction as compared to Controlled Attenuation Parameter for the severity of liver steatosis assessment - preliminary results. Medical Ultrasonography. https://doi.org/10.11152/mu-4575

Vancouver

Nica C, Sporea I, Popa A, Lupușoru R, Voicu Stan Erimescu M, Șirli R, et al. The value of Ultrasound Fat Fraction as compared to Controlled Attenuation Parameter for the severity of liver steatosis assessment - preliminary results. Medical Ultrasonography. 2026. doi:10.11152/mu-4575

BibTeX
@article{Nica2026,
  author = {Nica, Camelia and Sporea, Ioan and Popa, Alexandru and Lupușoru, Raluca and Voicu Stan Erimescu, Maria and Șirli, Roxana and Dănilă, Mirela and Boleac, Daiana and Plesa, Ariadna and Popescu, Alina},
  title = {The value of Ultrasound Fat Fraction as compared to Controlled Attenuation Parameter for the severity of liver steatosis assessment - preliminary results},
  journal = {Medical Ultrasonography},
  year = {2026},
  doi = {10.11152/mu-4575}
}
Kostenlos starten →