Preclinical Evaluation of the WAVE-track Aspiration Catheter: Safety and Efficacy in the Swine Thrombectomy Model
Academic Radiology · 2026-05 · 33 (5) · 2116-2127
DOI: 10.1016/j.acra.2026.01.013 ↗Kurz gefasst
Fachartikel in der Zeitschrift Academic Radiology, 2026-05. Verfasst von Biao Yang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, First Hospital of Shanxi Medical University, Taiyuan 030001, Shanxi Province, China (B.Y., Z.L., P.L., Y.C., X.W., X.G.);…. Hauptthemen laut MEDLINE: Thrombectomy, Catheters. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: We investigated the safety and effectiveness of the WAVE-track from the perspectives of imaging and pathology with a swine thrombectomy model to provide a basis for its clinical application, using the ACE aspiration catheter as the control group. MATERIALS AND METHODS: In a swine model, various types of thrombi were prepared and placed in the maxillary artery, ascending pharyngeal artery, lingual artery, and renal artery. The WAVE-track group was considered to be the study group, and the ACE aspiration catheter was used as the control group. Thrombectomy with the ADAPT technique or/and repeatedly pushed and withdrawn with aspiration were performed in two groups. The swine were sacrificed on the day of completion of procedure or at 30 ±5 days. RESULTS: According to the angiographic analysis, although the study group showed a better trend in mTICI distribution, no significant differences were recorded in the recanalization rates between the study group and the control group (mTICI≥2b: WAVE-track group 96.15% vs. ACE group 84.37%). Furthermore, the first-pass effect rates were similar in both groups (WAVE-track group 48.08% vs. ACE group 40.63%). Procedural safety was confirmed in both groups and pathological analysis revealed no clinically significant abnormalities in the two groups. In the subgroup analysis of single-pass and multiple-pass, there were no clinically significant differences found between the two pass types in angiographic and pathology assessment. CONCLUSION: Compared to the ACE catheter, the WAVE-track aspiration catheter demonstrated high thrombectomy efficacy and safety in a swine model. Additionally, the WAVE-track aspiration catheter demonstrated a favorable safety profile even after multiple thrombectomy passes, with no clinically significant increase in vascular injury compared to single pass.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, First Hospital of Shanxi Medical University, Taiyuan 030001, Shanxi Province, China (B.Y., Z.L., P.L., Y.C., X.W., X.G.); Cerebrovascular disease center, First Hospital of Shanxi Medical Univ…
- Cerebrovascular disease center, First Hospital of Shanxi Medical University, Taiyuan 030001, Shanxi Province, China (B.Y., Z.L., Y.W., R.L., P.L., Y.C., Z.Z., X.W., X.G., G.G.); Center for Cerebrovascular Diseases Resea…
- Key Laboratory of Environment and Female Reproductive Health, The Eighth Affiliated Hospital, Sun Yat-sen University, Guangdong Province 518033, China (H.Z.).
- Department of Neurosurgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China (Y.Z.).
Zitieren
APA
Yang, B., Li, Z., Wu, Y., Li, R., Li, P., Chen, Y., Zhou, Z., Wang, X., Guo, X., Zhang, H., Zhao, Y., & Guo, G. (2026). Preclinical Evaluation of the WAVE-track Aspiration Catheter: Safety and Efficacy in the Swine Thrombectomy Model. Academic Radiology, 33(5), 2116-2127. https://doi.org/10.1016/j.acra.2026.01.013
Vancouver
Yang B, Li Z, Wu Y, Li R, Li P, Chen Y, et al. Preclinical Evaluation of the WAVE-track Aspiration Catheter: Safety and Efficacy in the Swine Thrombectomy Model. Academic Radiology. 2026;33(5):2116-2127. doi:10.1016/j.acra.2026.01.013
BibTeX
@article{Yang2026,
author = {Yang, Biao and Li, Ziao and Wu, Yongqiang and Li, Ren and Li, Peize and Chen, Yang and Zhou, Zixuan and Wang, Xiaogang and Guo, Xiaolong and Zhang, Huidong and Zhao, Yuanli and Guo, Geng},
title = {Preclinical Evaluation of the WAVE-track Aspiration Catheter: Safety and Efficacy in the Swine Thrombectomy Model},
journal = {Academic Radiology},
year = {2026},
volume = {33},
number = {5},
pages = {2116--2127},
doi = {10.1016/j.acra.2026.01.013}
}
EUVIMED