Comparing Mean-anchored Generalized Linear Binning with Established Methods to Quantify Xenon-129 Ventilation Defect Percentage
Academic Radiology · 2026-02 · 33 (2) · 569-585
DOI: 10.1016/j.acra.2025.10.044 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Academic Radiology, 2026-02. Verfasst von Riaz Hussain und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH (R.H., A.S.B., J.W.P., B.I.M., M.M.W., L.L.W., Z.I.C.). Hauptthemen laut MEDLINE: Cystic Fibrosis, Magnetic Resonance Imaging, Xenon Isotopes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: Hyperpolarized xenon-129 (129Xe) MRI is an established, sensitive method to assess ventilation but lacks a standardized ventilation defect quantification. We introduce mean-anchored generalized linear binning (MeanGLB, GLB) to calculate ventilation defect percentage (VDP), benchmarking its performance against reader-segmented VDP (Reader) and five widely-used automated VDP calculation methods. MATERIALS AND METHODS: 129Xe images were acquired from 38 people with cystic fibrosis (CF) and 25 age-matched healthy controls (HCs) using 2D-spiral sequence. Flexible chest coil-induced inhomogeneities were mitigated using both N4- or a flip-angle (FA)-based bias correction. VDP was quantified using Reader, Hierarchical and Adaptive K-means clustering, mean-normalized linear binning, 99th Percentile-normalized GLB, binary Thresholding, and MeanGLB; and compared for all techniques. Additionally, VDPs obtained via automated methods were evaluated against Reader. Voxel-wise agreement with Reader-based defect maps was assessed using sensitivity, specificity and Youden's index. RESULTS: Using N4-corrected images, all methods-except Hierarchical-showed significant difference in VDP between participants with CF and HCs (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH (R.H., A.S.B., J.W.P., B.I.M., M.M.W., L.L.W., Z.I.C.).
- Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH (R.H., A.S.B., J.W.P., B.I.M., M.M.W., L.L.W., Z.I.C.); Department of Biomedical Engineering, University of Cincinnati, Cinci…
- Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH (R.H., A.S.B., J.W.P., B.I.M., M.M.W., L.L.W., Z.I.C.); Department of Pediatrics, University of Cincinnati, Cincinnati, OH (M…
Förderung
- NHLBI NIH HHS
- National Institutes of Health
Zitieren
APA
Hussain, R., Bdaiwi, A. S., Plummer, J. W., Masokano, B. I., Willmering, M. M., Walkup, L. L., & Cleveland, Z. I. (2026). Comparing Mean-anchored Generalized Linear Binning with Established Methods to Quantify Xenon-129 Ventilation Defect Percentage. Academic Radiology, 33(2), 569-585. https://doi.org/10.1016/j.acra.2025.10.044
Vancouver
Hussain R, Bdaiwi AS, Plummer JW, Masokano BI, Willmering MM, Walkup LL, et al. Comparing Mean-anchored Generalized Linear Binning with Established Methods to Quantify Xenon-129 Ventilation Defect Percentage. Academic Radiology. 2026;33(2):569-585. doi:10.1016/j.acra.2025.10.044
BibTeX
@article{Hussain2026,
author = {Hussain, Riaz and Bdaiwi, Abdullah S and Plummer, Joseph W and Masokano, Bilal I and Willmering, Matthew M and Walkup, Laura L and Cleveland, Zackary I},
title = {Comparing Mean-anchored Generalized Linear Binning with Established Methods to Quantify Xenon-129 Ventilation Defect Percentage},
journal = {Academic Radiology},
year = {2026},
volume = {33},
number = {2},
pages = {569--585},
doi = {10.1016/j.acra.2025.10.044}
}
EUVIMED