EUVIMEDEUVIMED entdecken
Crossref

Use of Ultra‐Short Echo Time MRI to Improve Temporal Bone Imaging

A C Kaufman iD, F Fu, M C Martinez, N Fischbein, G R Popelka, K Butts Pauly, N H Blevins

The Laryngoscope · 2024

DOI: 10.1002/lary.31707 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Laryngoscope, 2024. Verfasst von A C Kaufman und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology-Head and Neck Surgery, University of Maryland, Baltimore, Maryland, U.S.A. Hauptthemen laut MEDLINE: Temporal Bone, Magnetic Resonance Imaging, Neuroma, Acoustic, Tomography, X-Ray Computed. Die Arbeit nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The short T2 nature of cortical bone causes it to appear similar to air on MR, forcing clinicians to rely on computed tomography imaging, with its attendant ionizing radiation exposure, to define temporal bone structures. Through the use of novel MR sequences with ultra‐short echo times (UTE), short T2 structures are now able to be visualized, allowing for improved understanding of anatomical relationships.

Methods

Eight patients (50% female) undergoing MR imaging of the skull base for diagnostic purposes (62.5% for vestibular schwannoma surveillance) at a tertiary care center were enrolled to evaluate the safety and efficacy of UTE imaging. CT scans were completed in 37.5% of the patients as part of their workup and used for comparison purposes. The repetition time, short echo time, and long echo time for the UTE sequence were 11, 0.032, and 2.2 msec, respectively.

Results

The protocol added 6 min to the total scanning time, and all patients tolerated the sequence without issue. The ossicles, mastoid air cells, antrum, and epitympanum were able to be seen and had a high Dice similarity coefficient when compared to CT (>0.5). UTE allowed for clear delineation of all segments of the facial nerve with a signal‐to‐noise ratio of 35 (although the BRAVO sequences had a superior ratio of 140). Vestibular schwannomas were able to be distinguished from normal brain parenchyma.

Conclusions

UTE is safe and effective for visualizing anatomic structures not normally seen on traditional MRI, potentially allowing for improved surgical planning in patients. Level of Evidence 3 Laryngoscope , 134:4691–4696, 2024

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Temporal BoneMagnetic Resonance ImagingNeuroma, AcousticTomography, X-Ray ComputedHumansFemaleMaleMiddle AgedAdultAgedSkull Base

Stichwörter der Autor:innen

acoustic neuromascranial baseradiology

Autor:innen und Institutionen

  • Department of Otorhinolaryngology-Head and Neck Surgery, University of Maryland, Baltimore, Maryland, U.S.A.
  • Department of Otorhinolaryngology-Head and Neck Surgery, Stanford University, Palo Alto, California, U.S.A.
  • School of Medicine, Stanford University, Palo Alto, California, U.S.A.
  • Department of Radiology, Stanford University, Palo Alto, California, U.S.A.

ORCID-Profile: A C Kaufman

Zitieren

APA

Kaufman, A. C., Fu, F., Martinez, M. C., Fischbein, N., Popelka, G. R., Butts Pauly, K., & Blevins, N. H. (2024). Use of Ultra‐Short Echo Time MRI to Improve Temporal Bone Imaging. The Laryngoscope. https://doi.org/10.1002/lary.31707

Vancouver

Kaufman AC, Fu F, Martinez MC, Fischbein N, Popelka GR, Butts Pauly K, et al. Use of Ultra‐Short Echo Time MRI to Improve Temporal Bone Imaging. The Laryngoscope. 2024. doi:10.1002/lary.31707

BibTeX
@article{Kaufman2024,
  author = {Kaufman, A C and Fu, F and Martinez, M C and Fischbein, N and Popelka, G R and Butts Pauly, K and Blevins, N H},
  title = {Use of Ultra‐Short Echo Time MRI to Improve Temporal Bone Imaging},
  journal = {The Laryngoscope},
  year = {2024},
  doi = {10.1002/lary.31707}
}
Kostenlos starten →