Advancing Neurovascular Imaging: Optimization of Reconstruction Kernel and Quantum Iterative Reconstruction for Ultra-high-resolution Photon-Counting Detector CT Angiography of the Head and Neck
Academic Radiology · 2025
DOI: 10.1016/j.acra.2025.07.033 ↗Kurz gefasst
Fachartikel in der Zeitschrift Academic Radiology, 2025. Verfasst von Adrienn Tóth und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston 29425, SC (A.T., J.Y., J.C., E.W., J.J., M.G.M., E…. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Radiographic Image Interpretation, Computer-Assisted, Intracranial Aneurysm, Head. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: To find the optimal reconstruction parameters for ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) angiography of the head and neck, with a special focus on imaging intracranial aneurysms. MATERIAL AND METHODS: 18 patients with intracranial aneurysms were prospectively enrolled in this single-center study. CT angiograms were acquired in UHR mode on a clinical PCD-CT scanner. Images were reconstructed with six strength levels of a dedicated neurovascular kernel (Hv48-89) and with quantum iterative reconstruction (QIR) levels 1-4. Image noise, contrast-to-noise ratio, and vessel sharpness were determined for all reconstructions. Qualitative image quality was assessed by three readers using a 5-point Likert scale, for the best-performing reconstructions. Aneurysm dome and neck sizes were independently measured by two readers to assess inter-reader reliability. RESULTS: 18 patients (mean age, 64.3 years ± 15 [SD], 5 men,) were evaluated. Three kernels (Hv56, Hv64, Hv72) were identified as best performing in the quantitative analysis. The qualitative analysis demonstrated a consistent preference for QIR level 4 across all kernels in each evaluated category (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston 29425, SC (A.T., J.Y., J.C., E.W., J.J., M.G.M., E.B., M.V.S.); Medical Imaging Centre, Semmelweis University, Budapest,…
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston 29425, SC (A.T., J.Y., J.C., E.W., J.J., M.G.M., E.B., M.V.S.).
- Department of Neurosurgery, Medical University of South Carolina, Charleston 29425, SC (K.P.K., S.A.K.).
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston 29425, SC (A.T., J.Y., J.C., E.W., J.J., M.G.M., E.B., M.V.S.). Electronic address: spampin@musc.edu.
Zitieren
APA
Tóth, A., Cho, J. Y., Crow, J., Wilson, E., Kicielinski, K., Al Kasab, S., Joyce, J., Matheus, M. G., Bass, E., & Spampinato, M. V. (2025). Advancing Neurovascular Imaging: Optimization of Reconstruction Kernel and Quantum Iterative Reconstruction for Ultra-high-resolution Photon-Counting Detector CT Angiography of the Head and Neck. Academic Radiology. https://doi.org/10.1016/j.acra.2025.07.033
Vancouver
Tóth A, Cho JY, Crow J, Wilson E, Kicielinski K, Al Kasab S, et al. Advancing Neurovascular Imaging: Optimization of Reconstruction Kernel and Quantum Iterative Reconstruction for Ultra-high-resolution Photon-Counting Detector CT Angiography of the Head and Neck. Academic Radiology. 2025. doi:10.1016/j.acra.2025.07.033
BibTeX
@article{Tth2025,
author = {Tóth, Adrienn and Cho, Jennifer Yongjoo and Crow, John and Wilson, Evan and Kicielinski, Kimberly and Al Kasab, Sami and Joyce, Jennifer and Matheus, Maria Gisele and Bass, Eric and Spampinato, Maria Vittoria},
title = {Advancing Neurovascular Imaging: Optimization of Reconstruction Kernel and Quantum Iterative Reconstruction for Ultra-high-resolution Photon-Counting Detector CT Angiography of the Head and Neck},
journal = {Academic Radiology},
year = {2025},
doi = {10.1016/j.acra.2025.07.033}
}