AI-Based Automated Quantification of Arterial Stenosis in Head and Neck CT Angiography: A Comparison with Manual Measurements from Digital Subtraction Angiography and CT Angiography
Clinical Neuroradiology · 2025
DOI: 10.1007/s00062-024-01464-6 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical Neuroradiology, 2025. Verfasst von Xinyue Huan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The Second Affiliated Hospital of Chongqing Medical University & Chongqing Medical Imaging Artificial Intelligence Laborator…. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Angiography, Digital Subtraction, Head, Artificial Intelligence. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Construction of Plateau Discipline of Fujian Province.
Abstract (Originalsprache)
PURPOSE: To evaluate the performance of an artificial intelligence (AI) algorithm for automated quantification of arterial stenosis in head and neck CT angiography (CTA). METHODS: Patients who received head and neck CTA and DSA between January 2019 and December 2021 in two centers were included. The quantitative performance of CerebralDoc per-lesion was evaluated through intraclass correlation coefficients (ICCs) and Bland-Altman analysis, comparing automated stenosis measurements and manual measurements across 0-100%, < 50%, ≥ 50% and ≥ 70% thresholds. Sensitivity analysis included linear and logistic regression, and subgroups analysis was performed to identify influencing factors. RESULTS: 287 patients with 1765 lesions were analyzed. ICCs between CerebralDoc and DSA for ≥ 50% and ≥ 70% stenosis were excellent (0.955, 0.922, respectively), for 0-100% stenosis was good (0.735), and for < 50% stenosis was poor (0.056). For ≥ 50% and ≥ 70% stenosis of CerebralDoc and CTA manual measurements versus DSA, ICCs were close (0.955 vs 0.994; 0.922 vs 0.986), and differences were small (0.258% vs -0.362%; 0.369% vs -0.199%). The sensitivity analysis revealed that specific locations (V1, V2, V3, V4) and slender vessels have large or remarkable differences ranging from 15.551% to 44.238%. CONCLUSION: CerebralDoc exhibited excellent performance in automatically quantifying arterial stenosis of ≥ 50% and ≥ 70% in head and neck CTA. However, further research was needed to improve its performance for < 50% stenosis and to address differences in specific locations and slender vessels.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, The Second Affiliated Hospital of Chongqing Medical University & Chongqing Medical Imaging Artificial Intelligence Laboratory, No. 74 Linjiang Rd, Yuzhong District, 400010, Chongqing, China.
- Department of Radiology, Banan Hospital of Chongqing Medical University, No. 659 Yunan Avenue, Longzhouwan Street, Banan District, 401320, Chongqing, China.
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical and Pharmaceutical College, 301 Nancheng Avenue, Nanan District, 400060, Chongqing, China.
- Department of Radiology, The Fifth People's Hospital of Chongqing, No. 24 Renji Road, Nanan District, 400062, Chongqing, China.
- Department of Radiology, The Second Affiliated Hospital of Chongqing Medical University & Chongqing Medical Imaging Artificial Intelligence Laboratory, No. 74 Linjiang Rd, Yuzhong District, 400010, Chongqing, China. guo…
- Department of Radiology, The Second Affiliated Hospital of Chongqing Medical University & Chongqing Medical Imaging Artificial Intelligence Laboratory, No. 74 Linjiang Rd, Yuzhong District, 400010, Chongqing, China. lik…
Förderung
- Construction of Plateau Discipline of Fujian Province
Zitieren
APA
Huan, X., Yang, Y., Niu, S., Yang, Y., Tian, B., Guo, D., & Li, K. (2025). AI-Based Automated Quantification of Arterial Stenosis in Head and Neck CT Angiography: A Comparison with Manual Measurements from Digital Subtraction Angiography and CT Angiography. Clinical Neuroradiology. https://doi.org/10.1007/s00062-024-01464-6
Vancouver
Huan X, Yang Y, Niu S, Yang Y, Tian B, Guo D, et al. AI-Based Automated Quantification of Arterial Stenosis in Head and Neck CT Angiography: A Comparison with Manual Measurements from Digital Subtraction Angiography and CT Angiography. Clinical Neuroradiology. 2025. doi:10.1007/s00062-024-01464-6
BibTeX
@article{Huan2025,
author = {Huan, Xinyue and Yang, Yang and Niu, Shengwen and Yang, Yongwei and Tian, Bitong and Guo, Dajing and Li, Kunhua},
title = {AI-Based Automated Quantification of Arterial Stenosis in Head and Neck CT Angiography: A Comparison with Manual Measurements from Digital Subtraction Angiography and CT Angiography},
journal = {Clinical Neuroradiology},
year = {2025},
doi = {10.1007/s00062-024-01464-6}
}
EUVIMED