Deep Learning Image Reconstruction for Transcatheter Aortic Valve Implantation Planning: Image Quality, Diagnostic Performance, Contrast volume and Radiation Dose Assessment
Academic Radiology · 2024
DOI: 10.1016/j.acra.2024.02.026 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Academic Radiology, 2024. Verfasst von Yu Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, Sichuan 610041, China. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Deep Learning, Radiation Dosage, Contrast Media. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: To assess image quality, contrast volume and radiation dose reduction potential and diagnostic performance with the use of high-strength deep learning image reconstruction (DLIR-H) in transcatheter aortic valve implantation (TAVI) planning CT. METHODS: We prospectively enrolled 128 patients referred to TAVI-planning CT. Patients were randomly divided into two groups: DLIR-H group (n = 64) and conventional group (n = 64). The DLIR-H group was scanned with tube voltage of 80kVp and body weighted-dependent contrast injection rate of 28mgI/kg/s, images reconstructed using DLIR-H; the conventional group was scanned with 100kVp and contrast injection rate of 40mgI/kg/s, and images reconstructed using adaptive statistical iterative reconstruction-V at 50% (ASIR-V 50%). Radiation dose, contrast volume, contrast injection rate, and image quality were compared between the two groups. The diagnostic performance of TAVI planning CT for coronary stenosis in 115 patients were calculated using invasive coronary angiography as golden standard. RESULTS: DLIR-H group significantly reduced radiation dose (4.94 ± 0.39mSv vs. 7.93 ± 1.20mSv, p 50% stenosis. In the conventional group, the corresponding results were 94.7%, 95.3%, 97.6%, and 90.0%, respectively. CONCLUSION: DLIR-H in TAVI-planning CT provides improved image quality with reduced radiation and contrast doses, and enables satisfactory diagnostic performance for coronary arteries stenosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, Sichuan 610041, China.
- GE Healthcare, Beijing, China.
- Department of Radiology, West China Hospital, Sichuan University, 37 Guoxue Alley, Chengdu, Sichuan 610041, China. Electronic address: shuaitao1985@126.com.
Zitieren
APA
Zhang, Y., Liu, Z., Cheng, Y., Wang, Z., Li, Z., Li, J., & Shuai, T. (2024). Deep Learning Image Reconstruction for Transcatheter Aortic Valve Implantation Planning: Image Quality, Diagnostic Performance, Contrast volume and Radiation Dose Assessment. Academic Radiology. https://doi.org/10.1016/j.acra.2024.02.026
Vancouver
Zhang Y, Liu Z, Cheng Y, Wang Z, Li Z, Li J, et al. Deep Learning Image Reconstruction for Transcatheter Aortic Valve Implantation Planning: Image Quality, Diagnostic Performance, Contrast volume and Radiation Dose Assessment. Academic Radiology. 2024. doi:10.1016/j.acra.2024.02.026
BibTeX
@article{Zhang2024,
author = {Zhang, Yu and Liu, Zixuan and Cheng, Yong and Wang, Ziwei and Li, Zhenlin and Li, Jianying and Shuai, Tao},
title = {Deep Learning Image Reconstruction for Transcatheter Aortic Valve Implantation Planning: Image Quality, Diagnostic Performance, Contrast volume and Radiation Dose Assessment},
journal = {Academic Radiology},
year = {2024},
doi = {10.1016/j.acra.2024.02.026}
}