EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Assessing Image Quality and Diagnostic Performance of Quadruple-Low Coronary CT Angiography with Deep Learning in High-BMI Patients

Ke Qi, Shumeng Li, Luotong Wang, Jiangtao Zhao, Xiaohui Wang, Ping Hou, Dian Yuan, Yicun Zhang, Aobo Dun, Qian Tang, Mengyuan Zhang, Weiting Zhang und 2 weitere

Academic Radiology · 2026-08 · 33 (8) · 3373-3383

DOI: 10.1016/j.acra.2026.04.048 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Academic Radiology, 2026-08. Verfasst von Ke Qi und 13 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan 450052, China (K.Q.,…. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Coronary Angiography, Deep Learning, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit nennt 37 Literaturangaben. Gefördert von: Henan Provincial Science and Technology Research Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES To examine the feasibility of a quadruple-low protocol in coronary computed tomography angiography (CCTA) assisted by the deep learning image reconstruction (DLIR) for participants with high body mass index (BMI). MATERIALS AND METHODS This prospective study involved 180 participants (BMI of ≥ 25 kg/m2). Participants were randomly assigned to three groups: the standard-dose (SD) group in 100 kVp with adaptive statistical iterative reconstruction (ASIR-V 50%) using contrast media (CM) administration at an iodine load of 245 mgI/kg (Iohexol, 350 mgI/mL) with a 10 s injection time; the experimental group underwent imaging with 80 kVp and DLIR-H, using an iodine load of 128 mgI/kg with a 7 s injection time, representing the triple-low (TL) with 350 mgI/mL Iohexol and quadruple-low (QL) groups with 320 mgI/mL Iodixanol. Quantitative image quality evaluations included vascular attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR), while qualitative image quality and diagnostic performance were also assessed. RESULTS Compared to the SD group, the TL group achieved reductions of 29.4% in radiation dose, 47.5% in CM volume, and 23.5% in CM injection rate, while the QL group achieved reductions of 32.5% in radiation dose, 41.5% in CM volume, 14.5% in CM injection rate, and 9% in CM concentration. The image noise in the QL and TL groups were significantly lower than in the SD group (all p 0.05). CONCLUSION TL and QL CCTA protocols showed equivalent or superior image quality and diagnostic accuracy compared to the SD protocol and may serve as effective alternatives for reducing radiation dose and contrast media use in patients with high BMI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyCoronary AngiographyDeep LearningRadiographic Image Interpretation, Computer-AssistedBody Mass IndexCoronary Artery DiseaseHumansContrast MediaProspective StudiesFemaleMaleMiddle AgedRadiation DosageFeasibility StudiesIohexolAgedTriiodobenzoic AcidsSignal-To-Noise Ratio

Stichwörter der Autor:innen

Contrast doseCoronary CT angiographyDeep learning image reconstructionDiagnostic performanceRadiation dose

Substanzen

Contrast MediaIohexolTriiodobenzoic Acidsiodixanol

Autor:innen und Institutionen

  • The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan 450052, China (K.Q., S.L., J.Z., X.W., P.H., D.Y., Y.Z., A.D., Q.T., M.Z., W.Z., J.G., J.L…
  • CT Imaging Research Center, GE HealthCare China, Beijing, China (L.W.).

Förderung

  • Henan Provincial Science and Technology Research Project

Zitieren

APA

Qi, K., Li, S., Wang, L., Zhao, J., Wang, X., Hou, P., Yuan, D., Zhang, Y., Dun, A., Tang, Q., Zhang, M., Zhang, W., Gao, J., & Liu, J. (2026). Assessing Image Quality and Diagnostic Performance of Quadruple-Low Coronary CT Angiography with Deep Learning in High-BMI Patients. Academic Radiology, 33(8), 3373-3383. https://doi.org/10.1016/j.acra.2026.04.048

Vancouver

Qi K, Li S, Wang L, Zhao J, Wang X, Hou P, et al. Assessing Image Quality and Diagnostic Performance of Quadruple-Low Coronary CT Angiography with Deep Learning in High-BMI Patients. Academic Radiology. 2026;33(8):3373-3383. doi:10.1016/j.acra.2026.04.048

BibTeX
@article{Qi2026,
  author = {Qi, Ke and Li, Shumeng and Wang, Luotong and Zhao, Jiangtao and Wang, Xiaohui and Hou, Ping and Yuan, Dian and Zhang, Yicun and Dun, Aobo and Tang, Qian and Zhang, Mengyuan and Zhang, Weiting and Gao, Jianbo and Liu, Jie},
  title = {Assessing Image Quality and Diagnostic Performance of Quadruple-Low Coronary CT Angiography with Deep Learning in High-BMI Patients},
  journal = {Academic Radiology},
  year = {2026},
  volume = {33},
  number = {8},
  pages = {3373--3383},
  doi = {10.1016/j.acra.2026.04.048}
}
Kostenlos starten →