Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT
Academic Radiology · 2024-01 · 31 (1) · 212-220
DOI: 10.1016/j.acra.2023.06.025 ↗Kurz gefasst
Fachartikel in der Zeitschrift Academic Radiology, 2024-01. Verfasst von Giulia Cundari und 7 weiteren Autor:innen. Beteiligte Einrichtung: Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091, Zurich, Switzerland (G.C., P.D., V…. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Radiography, Dual-Energy Scanned Projection. Die Arbeit wurde bisher 53-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Bayer.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: To determine the optimal virtual monoenergetic image (VMI) energy level and the potential of contrast-media (CM) reduction for coronary computed tomography angiography (CCTA) with photon-counting detector CT (PCD-CT). MATERIALS AND METHODS: In this institutional review board-approved study, patients who underwent CCTA with dual-source PCD-CT with an identical scan protocol and radiation dose were included. In group 1, CCTA was performed with our standard CM protocol (volume: 72-85.2 mL, 370 mg iodine/mL). VMIs were reconstructed from 40 to 60 keV at 5 keV increments. Objective image quality (IQ) (vascular attenuation, image noise, and contrast-to-noise ratio [CNR]) was measured. Two blinded, independent readers rated subjective IQ (overall IQ, subjective image contrast, and subjective noise using a five-point discrete visual scale). Results of group 1 served to determine the best VMI level for CCTA. In group 2, CM volume was reduced by 20%, and in group 3 by another 20%. RESULTS: A total of 100 patients were enrolled (45 females, mean age 54 ± 13 years). Inter-reader agreement was good-to-excellent for all comparisons (κ > 0.6). In group 1, the best VMI level regarding objective and subjective IQ was 45 keV, which was selected as the reference for groups 2 and 3. For group 2, mean vascular attenuation was 890 Hounsfield units (HU) and mean CNR was 26, with no differences compared to group 1, 45 keV for both objective and subjective IQ. For group 3, mean vascular attenuation was 676 HU and mean CNR was 21, and all patients were rated as diagnostic except one (severe motion artifacts). CONCLUSION: Increased IQ of PCD-CT can be used for considerable CM volume reduction while still maintaining a diagnostic IQ of CCTA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091, Zurich, Switzerland (G.C., P.D., V.M., K.C., M.E., L.J., H.A., K.H.); Department of Radiological, Oncolo…
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091, Zurich, Switzerland (G.C., P.D., V.M., K.C., M.E., L.J., H.A., K.H.).
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091, Zurich, Switzerland (G.C., P.D., V.M., K.C., M.E., L.J., H.A., K.H.); Department of Radiology, Spital In…
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091, Zurich, Switzerland (G.C., P.D., V.M., K.C., M.E., L.J., H.A., K.H.). Electronic address: kai.higashigai…
Förderung
- Bayer
Zitieren
APA
Cundari, G., Deilmann, P., Mergen, V., Ciric, K., Eberhard, M., Jungblut, L., Alkadhi, H., & Higashigaito, K. (2024). Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT. Academic Radiology, 31(1), 212-220. https://doi.org/10.1016/j.acra.2023.06.025
Vancouver
Cundari G, Deilmann P, Mergen V, Ciric K, Eberhard M, Jungblut L, et al. Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT. Academic Radiology. 2024;31(1):212-220. doi:10.1016/j.acra.2023.06.025
BibTeX
@article{Cundari2024,
author = {Cundari, Giulia and Deilmann, Philipp and Mergen, Victor and Ciric, Kristina and Eberhard, Matthias and Jungblut, Lisa and Alkadhi, Hatem and Higashigaito, Kai},
title = {Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT},
journal = {Academic Radiology},
year = {2024},
volume = {31},
number = {1},
pages = {212--220},
doi = {10.1016/j.acra.2023.06.025}
}