EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access

The effect of excessive noise rejection, noise filtering and twitch threshold on mechanomyograph twitch measurements

Zain Wedemeyer, Andrew Bowdle, Srdjan Jelacic, Willis Silliman, Kelly E Michaelsen

Anaesthesia Critical Care & Pain Medicine · 2026-05 · 45 (3) · 101780

DOI: 10.1016/j.accpm.2026.101780 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Anaesthesia Critical Care & Pain Medicine, 2026-05. Verfasst von Zain Wedemeyer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, University of Washington, Seattle, WA, United States. Hauptthemen laut MEDLINE: Myography, Neuromuscular Blockade, Neuromuscular Monitoring, Signal Processing, Computer-Assisted. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, Foundation for Anesthesia Education and Research, National Institute of General Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Quantitative neuromuscular block monitoring devices would ideally produce similar results. However, there can be substantial differences in twitch measurements due to differences in noise management and signal processing. Optimal clinical application of these monitors requires an understanding of how noise management and signal processing affect the results. We used a noise management system for a laboratory-built mechanomyograph to determine the effect of excessive noise rejection, noise filtering, and twitch amplitude threshold on twitch measurements. METHODS: Twitch waveforms were collected using a mechanomyograph in patients under general anaesthesia. The mechanomyograph noise management system consisted of two parts: excessive noise detection and a signal processing algorithm. The system rejected waveforms containing excessive noise. Waveform signal noise was then filtered, and a minimum amplitude threshold was applied to define a twitch. The performance of the noise detection algorithm was compared to manual noise detection by inspecting each waveform. Two parameters within the signal processing algorithm (filtering level and amplitude threshold) were varied, and their effect on the twitch measurements was assessed. RESULTS: A total of 4,371 twitch measurements were collected from 29 patients. A Cohen's kappa value of 0.82 indicated "almost perfect" agreement between the excessive noise detection algorithm and manual detection. Varying the filtering level and amplitude threshold had a substantial effect on train-of-four counts, with a maximum average difference in count of 0.8, but had a negligible effect on train-of-four ratios. CONCLUSIONS: A noise management system for a laboratory-built mechanomyograph showed excellent agreement with the manual interpretation of twitch waveforms. Varying the noise filtering level and amplitude threshold had a substantial effect on train-of-four counts but a minimal effect on train-of-four ratios. REGISTRATION: ClinicalTrials.gov (NCT05006807).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MyographyNeuromuscular BlockadeNeuromuscular MonitoringSignal Processing, Computer-AssistedAdultFemaleHumansMaleMiddle AgedAlgorithmsAnesthesia, GeneralSignal-To-Noise Ratio

Stichwörter der Autor:innen

MechanomyographyMedical devicesNeuromuscular block monitoringQuantitative monitoringTrain-of-four monitoringTwitch monitoring

Autor:innen und Institutionen

  • Department of Anesthesiology, University of Washington, Seattle, WA, United States.
  • Department of Anesthesiology, University of Washington, Seattle, WA, United States. Electronic address: kellyem@uw.edu.

Förderung

  • NIGMS NIH HHS
  • Foundation for Anesthesia Education and Research
  • National Institute of General Medical Sciences

Zitieren

APA

Wedemeyer, Z., Bowdle, A., Jelacic, S., Silliman, W., & Michaelsen, K. E. (2026). The effect of excessive noise rejection, noise filtering and twitch threshold on mechanomyograph twitch measurements. Anaesthesia Critical Care & Pain Medicine, 45(3), 101780. https://doi.org/10.1016/j.accpm.2026.101780

Vancouver

Wedemeyer Z, Bowdle A, Jelacic S, Silliman W, Michaelsen KE. The effect of excessive noise rejection, noise filtering and twitch threshold on mechanomyograph twitch measurements. Anaesthesia Critical Care & Pain Medicine. 2026;45(3):101780. doi:10.1016/j.accpm.2026.101780

BibTeX
@article{Wedemeyer2026,
  author = {Wedemeyer, Zain and Bowdle, Andrew and Jelacic, Srdjan and Silliman, Willis and Michaelsen, Kelly E},
  title = {The effect of excessive noise rejection, noise filtering and twitch threshold on mechanomyograph twitch measurements},
  journal = {Anaesthesia Critical Care & Pain Medicine},
  year = {2026},
  volume = {45},
  number = {3},
  pages = {101780},
  doi = {10.1016/j.accpm.2026.101780}
}
Kostenlos starten →