Evolution of a laboratory mechanomyograph
Journal of Clinical Monitoring and Computing · 2024
DOI: 10.1007/s10877-024-01175-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Monitoring and Computing, 2024. Verfasst von Zain Wedemeyer und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, University of Washington, Box 356540, 1959 NE Pacific Street, Seattle, WA, 98195-6540, USA. Hauptthemen laut MEDLINE: Equipment Design, Neuromuscular Blockade, Myography. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIGMS NIH HHS, Foundation of Anesthesia Education and Research, Washington Research Foundation.
Abstract (Originalsprache)
Mechanomyography is currently the accepted laboratory reference standard for quantitative neuromuscular blockade monitoring. Mechanomyographs are not commercially available. Previously, a mechanomyograph was built by our laboratory and used in several clinical studies. It was subsequently redesigned to improve its usability and functionality and to accommodate a wider range of hand sizes and shapes using an iterative design process. Each version of the redesigned device was initially tested for usability and functionality in the lab with the investigators as subjects without electrical stimulation. The redesigned devices were then assessed on patients undergoing elective surgery under general anesthesia without neuromuscular blocking drugs. Since the patients were not paralyzed, the expected train-of-four ratio was 1.0. The device accuracy and precision were represented by the train-of-four ratio mean and standard deviation. If issues with the device’s useability or functionality were discovered, changes were made, and the redesign processes repeated. The final mechanomyograph design was used to collect 2,362 train-of-four ratios from 21 patients. The mean and standard deviation of the train-of-four ratios were 0.99 ± 0.030. Additionally, the final mechanomyograph design was easier to use and adjust than the original design and fit a wider range of hand sizes. The final design also reduced the frequency of adjustments and the time needed for adjustments, facilitating data collection during a surgical procedure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, University of Washington, Box 356540, 1959 NE Pacific Street, Seattle, WA, 98195-6540, USA.
- Department of Anesthesiology, University of Washington, Box 356540, 1959 NE Pacific Street, Seattle, WA, 98195-6540, USA. kellyem@uw.edu.
Förderung
- NIGMS NIH HHS
- Foundation of Anesthesia Education and Research
- Washington Research Foundation
- Laura Cheney Professorship in Anesthesia Patient Safety
Zitieren
APA
Wedemeyer, Z., Bowdle, A., Jelacic, S., Lopez, A., Silliman, W., & Michaelsen, K. E. (2024). Evolution of a laboratory mechanomyograph. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-024-01175-w
Vancouver
Wedemeyer Z, Bowdle A, Jelacic S, Lopez A, Silliman W, Michaelsen KE. Evolution of a laboratory mechanomyograph. Journal of Clinical Monitoring and Computing. 2024. doi:10.1007/s10877-024-01175-w
BibTeX
@article{Wedemeyer2024,
author = {Wedemeyer, Zain and Bowdle, Andrew and Jelacic, Srdjan and Lopez, Aidan and Silliman, Willis and Michaelsen, Kelly E},
title = {Evolution of a laboratory mechanomyograph},
journal = {Journal of Clinical Monitoring and Computing},
year = {2024},
doi = {10.1007/s10877-024-01175-w}
}
EUVIMED