EUVIMEDEUVIMED entdecken
Crossref

Flavin mononucleotide-based biomimetic redox flow biosensor for rapid miRNA-21 detection in colorectal cancer diagnostics

Nan Ma, Yuelan Fang, Xiaoran Wu, Xiaohui Liu, Hui Jiang, Jinming Kong, Xuemei Wang

Analytica Chimica Acta · 2026-12 · 1426 · 346340

DOI: 10.1016/j.aca.2026.346340 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-12. Verfasst von Nan Ma und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, PR …. Hauptthemen laut MEDLINE: Biosensing Techniques, MicroRNAs, Colorectal Neoplasms, Flavin Mononucleotide. Die Arbeit nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Detection of tumor biomarkers in serum and cellular samples is essential for early diagnosis and precision treatment of colorectal cancer, and miRNA-21 is well-established as a pivotal oncogenic biomarker for this malignancy. Conventional nucleic acid detection methods typically rely on complex enzymatic amplification and lengthy workflows, severely restricting their application in point-of-care clinical screening and long-term dynamic disease monitoring. In this work, a novel biomimetic redox flow biosensor based on flavin mononucleotide (FMN) is developed for rapid quantitative detection of miRNA-21, marking the first application of FMN as an electroactive tag for trace nucleic acid analysis. The sensing mechanism centers on Ti4+ as a multifunctional coordination bridge, which forms stable bonds simultaneously with phosphate moieties of FMN and the phosphate backbone of target miRNA-21. This multisite coordination strategy enables ultrahigh detection sensitivity without additional signal amplification procedures. The fabricated biosensor exhibits an excellent linear response for miRNA-21 detection across 1∼10000 pM, with a detection limit as low as 0.18 pM. It converts biological recognition events into distinguishable electrochemical signals within 1 h under mild conditions, and shows outstanding selectivity and anti-interference capability in complex biological matrices. Notably, the system supports real-time data viewing and storage via mobile terminals, enabling IoT-compatible personalized health management and long-term dynamic monitoring. This portable biosensor suits high-throughput clinical colorectal cancer screening, facilitating early clinical intervention and precise tumor treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMicroRNAsColorectal NeoplasmsFlavin MononucleotideHumansOxidation-ReductionElectrochemical TechniquesLimit of DetectionBiomimetics

Stichwörter der Autor:innen

Biomimetic redox flowElectrochemical biosensorFlavin mononucleotideNucleic acid detection

Substanzen

MicroRNAsMIRN21 microRNA, humanFlavin Mononucleotide

Autor:innen und Institutionen

  • State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, PR China; School of Environmental and Biological Engineering, Nanjing Uni…
  • State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, PR China.
  • School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu, 210094, PR China. Electronic address: j.kong@njust.edu.cn.
  • State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, PR China. Electronic address: xuemei@seu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Ma, N., Fang, Y., Wu, X., Liu, X., Jiang, H., Kong, J., & Wang, X. (2026). Flavin mononucleotide-based biomimetic redox flow biosensor for rapid miRNA-21 detection in colorectal cancer diagnostics. Analytica Chimica Acta, 1426, 346340. https://doi.org/10.1016/j.aca.2026.346340

Vancouver

Ma N, Fang Y, Wu X, Liu X, Jiang H, Kong J, et al. Flavin mononucleotide-based biomimetic redox flow biosensor for rapid miRNA-21 detection in colorectal cancer diagnostics. Analytica Chimica Acta. 2026;1426:346340. doi:10.1016/j.aca.2026.346340

BibTeX
@article{Ma2026,
  author = {Ma, Nan and Fang, Yuelan and Wu, Xiaoran and Liu, Xiaohui and Jiang, Hui and Kong, Jinming and Wang, Xuemei},
  title = {Flavin mononucleotide-based biomimetic redox flow biosensor for rapid miRNA-21 detection in colorectal cancer diagnostics},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1426},
  pages = {346340},
  doi = {10.1016/j.aca.2026.346340}
}
Kostenlos starten →