Constraint Coupling of Redox Cascade and Electron Transfer Synchronization on Electrode‐Nanosensor Interface for Repeatable Detection of Tumor Biomarkers
Small Methods · 2024
DOI: 10.1002/smtd.202301330 ↗Kurz gefasst
Fachartikel in der Zeitschrift Small Methods, 2024. Verfasst von Xiyue Xie und 8 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, No. 174 Shazheng Roa…. Hauptthemen laut MEDLINE: Biomarkers, Tumor, MicroRNAs, Oxidation-Reduction, Biosensing Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities, 100 Talents Program of Chongqing University.
Abstract (Originalsprache)
Quantitative analysis of up‐regulated biomarkers in pathological tissues is helpful to tumor surgery yet the loss of biomarker extraction and time‐consuming operation limited the accurate and quick judgement in preoperative or intraoperative diagnosis. Herein, an immobilization‐free electrochemical sensing platform is developed by constraint coupling of electron transfer cascade on electrode‐nanosensor interface. Specifically, electrochemical indicator (Ri)‐labeled single‐stranded DNA on electroactive nanodonor (polydopamine, PDA) can be responsively detached by formation of DNA complex through the recognition and binding with targets. By applying the oxidation potential of Ri, nanosensor collisions on electrode surface trigger a cascade redox cycling of PDA and Ri through synchronous electron transfer, which boost the amplification of current signal output. The developed nanosensor exhibit excellent linear response toward up‐regulated biomarkers (miRNA‐21, ATP, and VEGF) with low detection limits (32 fM, 386 pM, and 2.8 pM). Moreover, background influence from physiological interferent is greatly reduced by restricted electron transfer coupling on electrode. The practical applicability is illustrated in sensitive and highly repeatable profiling of miRNA‐21 in lysate of tumor cells and tumor tissue, beneficial for more reliable diagnosis. This electrochemical platform by employing electron transfer cascades at heterogeneous interfaces offers a route to anti‐interference detection of biomarkers in tumor tissues.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, No. 174 Shazheng Road, Chongqing, 400044, China.
ORCID-Profile: Jixi Zhang
Förderung
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
- 100 Talents Program of Chongqing University
- Natural Science Foundation of Chongqing Municipality
Zitieren
APA
Xie, X., Jin, K., Wang, Z., Wang, S., Zhu, J., Huang, J., Tang, S., Cai, K., & Zhang, J. (2024). Constraint Coupling of Redox Cascade and Electron Transfer Synchronization on Electrode‐Nanosensor Interface for Repeatable Detection of Tumor Biomarkers. Small Methods. https://doi.org/10.1002/smtd.202301330
Vancouver
Xie X, Jin K, Wang Z, Wang S, Zhu J, Huang J, et al. Constraint Coupling of Redox Cascade and Electron Transfer Synchronization on Electrode‐Nanosensor Interface for Repeatable Detection of Tumor Biomarkers. Small Methods. 2024. doi:10.1002/smtd.202301330
BibTeX
@article{Xie2024,
author = {Xie, Xiyue and Jin, Kaifei and Wang, Zhenqiang and Wang, Shuai and Zhu, Jing and Huang, Jixi and Tang, Shuqi and Cai, Kaiyong and Zhang, Jixi},
title = {Constraint Coupling of Redox Cascade and Electron Transfer Synchronization on Electrode‐Nanosensor Interface for Repeatable Detection of Tumor Biomarkers},
journal = {Small Methods},
year = {2024},
doi = {10.1002/smtd.202301330}
}
EUVIMED