EUVIMEDEUVIMED entdecken
Crossref

Constraint Coupling of Redox Cascade and Electron Transfer Synchronization on Electrode‐Nanosensor Interface for Repeatable Detection of Tumor Biomarkers

Xiyue Xie, Kaifei Jin, Zhenqiang Wang, Shuai Wang, Jing Zhu, Jixi Huang, Shuqi Tang, Kaiyong Cai, Jixi Zhang iD

Small Methods · 2024

DOI: 10.1002/smtd.202301330 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small Methods, 2024. Verfasst von Xiyue Xie und 8 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, No. 174 Shazheng Roa…. Hauptthemen laut MEDLINE: Biomarkers, Tumor, MicroRNAs, Oxidation-Reduction, Biosensing Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities, 100 Talents Program of Chongqing University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative analysis of up‐regulated biomarkers in pathological tissues is helpful to tumor surgery yet the loss of biomarker extraction and time‐consuming operation limited the accurate and quick judgement in preoperative or intraoperative diagnosis. Herein, an immobilization‐free electrochemical sensing platform is developed by constraint coupling of electron transfer cascade on electrode‐nanosensor interface. Specifically, electrochemical indicator (Ri)‐labeled single‐stranded DNA on electroactive nanodonor (polydopamine, PDA) can be responsively detached by formation of DNA complex through the recognition and binding with targets. By applying the oxidation potential of Ri, nanosensor collisions on electrode surface trigger a cascade redox cycling of PDA and Ri through synchronous electron transfer, which boost the amplification of current signal output. The developed nanosensor exhibit excellent linear response toward up‐regulated biomarkers (miRNA‐21, ATP, and VEGF) with low detection limits (32 fM, 386 pM, and 2.8 pM). Moreover, background influence from physiological interferent is greatly reduced by restricted electron transfer coupling on electrode. The practical applicability is illustrated in sensitive and highly repeatable profiling of miRNA‐21 in lysate of tumor cells and tumor tissue, beneficial for more reliable diagnosis. This electrochemical platform by employing electron transfer cascades at heterogeneous interfaces offers a route to anti‐interference detection of biomarkers in tumor tissues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biomarkers, TumorMicroRNAsOxidation-ReductionBiosensing TechniquesElectrodesElectrochemical TechniquesHumansElectron TransportPolymersIndolesDNA, Single-StrandedVascular Endothelial Growth Factor AAdenosine TriphosphateNeoplasmsLimit of DetectionCell Line, Tumor

Stichwörter der Autor:innen

biomarker sensingcascade reactionconstraint couplingelectron transferinterface collision

Substanzen

Biomarkers, TumorMicroRNAsPolymerspolydopamineMIRN21 microRNA, humanIndolesDNA, Single-StrandedVascular Endothelial Growth Factor AAdenosine Triphosphate

Autor:innen und Institutionen

  • Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, No. 174 Shazheng Road, Chongqing, 400044, China.

ORCID-Profile: Jixi Zhang

Förderung

  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities
  • 100 Talents Program of Chongqing University
  • Natural Science Foundation of Chongqing Municipality

Zitieren

APA

Xie, X., Jin, K., Wang, Z., Wang, S., Zhu, J., Huang, J., Tang, S., Cai, K., & Zhang, J. (2024). Constraint Coupling of Redox Cascade and Electron Transfer Synchronization on Electrode‐Nanosensor Interface for Repeatable Detection of Tumor Biomarkers. Small Methods. https://doi.org/10.1002/smtd.202301330

Vancouver

Xie X, Jin K, Wang Z, Wang S, Zhu J, Huang J, et al. Constraint Coupling of Redox Cascade and Electron Transfer Synchronization on Electrode‐Nanosensor Interface for Repeatable Detection of Tumor Biomarkers. Small Methods. 2024. doi:10.1002/smtd.202301330

BibTeX
@article{Xie2024,
  author = {Xie, Xiyue and Jin, Kaifei and Wang, Zhenqiang and Wang, Shuai and Zhu, Jing and Huang, Jixi and Tang, Shuqi and Cai, Kaiyong and Zhang, Jixi},
  title = {Constraint Coupling of Redox Cascade and Electron Transfer Synchronization on Electrode‐Nanosensor Interface for Repeatable Detection of Tumor Biomarkers},
  journal = {Small Methods},
  year = {2024},
  doi = {10.1002/smtd.202301330}
}
Kostenlos starten →