Bioluminescent enzyme immunoassay for cortisol by exploitation of single-chain variable fragment and single-chain variable fragment-nanoluciferase fusion protein

Xiping Cui, Qiyi He, Huiyi Yang, Mingxia Lin, Suqing Zhao, Yunping Mu

Analytica Chimica Acta · 2026

DOI: 10.1016/j.aca.2026.346059 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Xiping Cui und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, 510006, People…. Hauptthemen laut MEDLINE: Single-Chain Antibodies, Hydrocortisone, Luciferases, Luminescent Measurements. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Guangdong Basic and Applied Basic Research Foundation, Basic and Applied Basic Research Foundation of Guangdong Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Measurement of cortisol levels is still a complex multi-step process in immunoassay. The isolation of single-chain variable fragment (scFv) from phage-display library is an effective approach to generate antibody-enzyme fusion protein, which can be used to improve the performance of immunoassay. RESULTS: In this work, the specific scFv against cortisol was isolated from native chicken-derived phage display library by the stringent bio-panning strategy. The obtained scFv was further fused with nanoluciferase (Nluc), named scFv-Nluc. Compared with scFv-based enzyme-linked immunosorbent assay (ELISA), the bioluminescent enzyme immunoassay (BLEIA) based on scFv-Nluc was conducted in one-step strategy, which could reduce the assay time. The half maximal inhibitory concentration (IC50) of the one-step BLEIA was calculated to be 203 ng/mL, which was 5-fold lower than the scFv-based ELISA (IC50 of 1139 ng/mL). When the BLEIA and ELISA are applied to serum samples subjected to 200-fold dilution, the corresponding original-serum equivalent IC50 values are 41 μg/mL for BLEIA and 228 μg/mL for ELISA, respectively. The established BLEIA exhibited excellent selectivity for cortisol among the analogues, while the satisfactory recoveries between 85.1 % and 120.1 % were obtained. SIGNIFICANCE: The results above demonstrated that both scFv and scFv-Nluc could be utilized as useful reagents for immunoassay, but the scFv-Nluc-based BLEIA could further enhance the performance of immunoassay, which may represent the promising method for cortisol analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Single-Chain AntibodiesHydrocortisoneLuciferasesLuminescent MeasurementsAnimalsRecombinant Fusion ProteinsChickensHumansImmunoenzyme TechniquesEnzyme-Linked Immunosorbent AssayPeptide Library

Stichwörter der Autor:innen

Antibody-enzyme fusion proteinCortisolImmunoassayNanoluciferaseSingle-chain variable fragment

Substanzen

Single-Chain AntibodiesHydrocortisoneRecombinant Fusion ProteinsLuciferasesPeptide Library

Autor:innen und Institutionen

  • Department of Biomedical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, 510006, People's Republic of China.
  • Department of Biomedical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, 510006, People's Republic of China; School of Food Science and Engineering, Key Labo…
  • Department of Biomedical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, 510006, People's Republic of China. Electronic address: muyunping2018@gdut.edu.cn.

Förderung

  • Guangdong Basic and Applied Basic Research Foundation
  • Basic and Applied Basic Research Foundation of Guangdong Province
  • National Natural Science Foundation of China

Zitieren

APA

Cui, X., He, Q., Yang, H., Lin, M., Zhao, S., & Mu, Y. (2026). Bioluminescent enzyme immunoassay for cortisol by exploitation of single-chain variable fragment and single-chain variable fragment-nanoluciferase fusion protein. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.346059

Vancouver

Cui X, He Q, Yang H, Lin M, Zhao S, Mu Y. Bioluminescent enzyme immunoassay for cortisol by exploitation of single-chain variable fragment and single-chain variable fragment-nanoluciferase fusion protein. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.346059

BibTeX
@article{Cui2026,
  author = {Cui, Xiping and He, Qiyi and Yang, Huiyi and Lin, Mingxia and Zhao, Suqing and Mu, Yunping},
  title = {Bioluminescent enzyme immunoassay for cortisol by exploitation of single-chain variable fragment and single-chain variable fragment-nanoluciferase fusion protein},
  journal = {Analytica Chimica Acta},
  year = {2026},
  doi = {10.1016/j.aca.2026.346059}
}