EUVIMEDEUVIMED entdecken
Crossref

The use of bioluminescent enzyme bioassay for the analysis of human saliva: Advantages and disadvantages

Oksana A Kolenchukova, Anastasia O Dedora, Lyudmila V Stepanova iD, Vlada U Kravchuk, Valentina A Kratasyuk

Luminescence · 2024

DOI: 10.1002/bio.4776 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Luminescence, 2024. Verfasst von Oksana A Kolenchukova und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Fundamental Biology and Biotechnology, Siberian Federal University, Krasnoyarsk, Russia. Hauptthemen laut MEDLINE: Saliva, Luminescent Measurements. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Strategic Academic Leadership Program "Priority 2030".

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The purpose of the work was to find optimal conditions for bioluminescent enzymatic analysis of saliva (based on the use of NADH:FMN oxidoreductase + luciferase) and then to determine the biological effect of using bioluminescence assay of saliva to study the physiological state of the body under normal and pathological conditions. The saliva of snowboarders and students were studied in the “rest–training” model. The saliva of patients diagnosed with acute pharyngitis was examined in the “sick–healthy” model. Bioluminescence assay was performed with a lyophilized and immobilized bi‐enzyme system using cuvette, plate, and portable luminometers. The concentrations of secretory immunoglobulin A (sIgA) and cortisol were determined by enzyme immunoassay, and the total protein content was measured by spectrophotometric method. The activity of the bioluminescent system enzymes increased as the amount and volume of saliva in the sample was decreased. The cuvette and plate luminometers were sensitive to changes in the luminescence intensity in saliva assay. Luminescence intensity correlated with the concentrations of sIgA and cortisol. The integrated bioluminescent index for saliva was reduced in the “rest–training” model and increased in the “sick–healthy” model. Thus, the non‐invasive bioluminescent saliva analysis may be a promising tool for assessing the health of the population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SalivaLuminescent MeasurementsHumansBiological AssayHydrocortisoneLuciferasesImmunoglobulin A, Secretory

Stichwörter der Autor:innen

NADH:FMN oxidoreductase + reductasebioluminescencebiomarkerssaliva

Substanzen

HydrocortisoneLuciferasesImmunoglobulin A, Secretory

Autor:innen und Institutionen

  • School of Fundamental Biology and Biotechnology, Siberian Federal University, Krasnoyarsk, Russia.
  • Research Institute of Medical Problems of the North, Federal Research Center "Krasnoyarsk Science Center of the Siberian Branch of the Russian Academy of Sciences", Krasnoyarsk, Russia.
  • Krasnoyarsk State Agrarian University, Krasnoyarsk, Russia.
  • Institute of Biophysics, Federal Research Center "Krasnoyarsk Science Center of the Siberian Branch of the Russian Academy of Sciences", Krasnoyarsk, Russia.

ORCID-Profile: Lyudmila V Stepanova

Förderung

  • Strategic Academic Leadership Program "Priority 2030"

Zitieren

APA

Kolenchukova, O. A., Dedora, A. O., Stepanova, L. V., Kravchuk, V. U., & Kratasyuk, V. A. (2024). The use of bioluminescent enzyme bioassay for the analysis of human saliva: Advantages and disadvantages. Luminescence. https://doi.org/10.1002/bio.4776

Vancouver

Kolenchukova OA, Dedora AO, Stepanova LV, Kravchuk VU, Kratasyuk VA. The use of bioluminescent enzyme bioassay for the analysis of human saliva: Advantages and disadvantages. Luminescence. 2024. doi:10.1002/bio.4776

BibTeX
@article{Kolenchukova2024,
  author = {Kolenchukova, Oksana A and Dedora, Anastasia O and Stepanova, Lyudmila V and Kravchuk, Vlada U and Kratasyuk, Valentina A},
  title = {The use of bioluminescent enzyme bioassay for the analysis of human saliva: Advantages and disadvantages},
  journal = {Luminescence},
  year = {2024},
  doi = {10.1002/bio.4776}
}
Kostenlos starten →