Chloride-assisted microwave-assisted digestion for reliable ICP–OES determination of tin in industrial wastewater: Method development and ISO 17025 validation

Asuhan Tepe, Elif Hatice Gürkan

Analytica Chimica Acta · 2026-09 · 1416 · 345730

DOI: 10.1016/j.aca.2026.345730 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-09. Verfasst von Asuhan Tepe und 1 weiteren Autor:innen. Beteiligte Einrichtung: Samsun Organized Industrial Zone Wastewater Treatment Plant, Turkey. Die Arbeit nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate determination of tin (Sn) in industrial wastewater by inductively coupled plasma-optical emission spectrometry (ICP-OES) is compromised by the susceptibility of Sn4+ to hydrolysis, precipitation, and volatilization during conventional nitric acid digestion. This study presents the development and full validation of a chloride-assisted microwave digestion protocol that stabilizes tin through in situ formation of stable tin (IV) chloro-complexes (including [SnCl6]2- and related species), thereby suppressing analyte loss and enabling reliable quantification in complex industrial effluent matrices. A direct experimental comparison of HNO3-only and HCl-assisted microwave-assisted digestion showed that, although the difference did not reach statistical significance (two-tailed t-test, t = 1.47, df = 12, p = 0.167), Sn concentrations were consistently lower under HNO3 digestion across all seven replicates (48.95 vs. 51.51 μg/L), indicating a systematic negative bias attributable to the known instability of Sn4+ in oxidizing acidic media - where hydrolysis, precipitation as metastannic acid, and partial volatilization collectively compromise analyte recovery. The method was validated in full compliance with ISO/IEC 17025:2017, encompassing linearity, repeatability, intermediate precision, trueness, robustness, and measurement uncertainty. The calibration curve exhibited excellent linearity over the range 10-2500 μg/L (R2 ≥ 0.999; slope = 0.8853). Precision was high across all concentration levels (RSD 0.94-6.95%). Spike recoveries in the wastewater matrix ranged from 86 to 100%. Limits of detection and quantification were 12.10 μg/L and 40.33 μg/L, respectively. Robustness assessment using a Plackett-Burman design with seven analytical factors confirmed that minor variations in instrumental and operational parameters did not significantly affect method performance (all Ex < Ecrit = 4.58). To the best of our knowledge, this is among the first studies to provide a chloride-assisted microwave-assisted digestion protocol for tin determination specifically in organized industrial zone wastewater, validated in full accordance with ISO/IEC 17025:2017 and including Plackett-Burman robustness testing. The method offers a practically implementable, matrix-appropriate solution for accredited environmental laboratories engaged in regulatory monitoring of tin in industrial effluents.

Schlagwörter

Stichwörter der Autor:innen

Chloride-assisted digestionICP–OESISO/IEC 17025Industrial wastewaterMethod validationMicrowave-assisted digestionTin

Autor:innen und Institutionen

  • Samsun Organized Industrial Zone Wastewater Treatment Plant, Turkey.
  • Department of Chemical Engineering, Ondokuz Mayıs University, Samsun, 55139, Turkey. Electronic address: elif.gurkan@omu.edu.tr.

Zitieren

APA

Tepe, A., & Gürkan, E. H. (2026). Chloride-assisted microwave-assisted digestion for reliable ICP–OES determination of tin in industrial wastewater: Method development and ISO 17025 validation. Analytica Chimica Acta, 1416, 345730. https://doi.org/10.1016/j.aca.2026.345730

Vancouver

Tepe A, Gürkan EH. Chloride-assisted microwave-assisted digestion for reliable ICP–OES determination of tin in industrial wastewater: Method development and ISO 17025 validation. Analytica Chimica Acta. 2026;1416:345730. doi:10.1016/j.aca.2026.345730

BibTeX
@article{Tepe2026,
  author = {Tepe, Asuhan and Gürkan, Elif Hatice},
  title = {Chloride-assisted microwave-assisted digestion for reliable ICP–OES determination of tin in industrial wastewater: Method development and ISO 17025 validation},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1416},
  pages = {345730},
  doi = {10.1016/j.aca.2026.345730}
}
Kostenlos starten →