EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Overcoming Incomplete Digestion of Ti-Doped LiFePO4 Cathode Materials: Microwave-Assisted Sample Preparation and Single-Laboratory Validated ICP-OES Determination of Li, Fe, P, and Ti

Myung-Gyu Lee iD, Tae-Young Kim, Sam-Hang Yi, Joo-Seok Park, Young-Jun Yoon, Kyoung-Seok Moon iD

Molecules · 30.10.2026 · 31 (21) · 3915

DOI: 10.3390/molecules31213915 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 30.10.2026. Verfasst von Myung-Gyu Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science & Engineering, Gyeongsang National University, Jinju 52828, Republic of Korea. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Trade, Industry and Resources.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reliable compositional quality control of Ti-doped LiFePO4 (LFP) requires quantitative release of the low-level Ti dopant from a carbon-coated phosphate matrix. We evaluated aqua regia hot-plate digestion and developed a closed-vessel microwave digestion–inductively coupled plasma optical emission spectrometry (ICP-OES) method for Li, Fe, P, and Ti. Aqua regia left a carbon-rich residue containing Ti; mass balance on seven digestions showed that 5.86 ± 0.37% of total Ti was retained, compared with 0.39 ± 0.12%, 0.53 ± 0.11%, and 0.81 ± 0.13% for Li, Fe, and P. The mean Ti recovery across the 14 aqua regia digestions was 92.8% of the assigned value, compared with 100.0% for the microwave procedure. Digestion with 6 mL HNO3 and 2 mL HCl at 240 °C gave quantitative Ti release: between 220 and 240 °C the Ti result rose by 14.0% to a plateau, while Li, Fe, and P changed by less than 2%. Calibration R2 values exceeded 0.999. Recoveries were 98.6–99.8%, repeatability RSDs 0.49–1.51%, and relative expanded uncertainties 0.64–2.20%; the lower calibration limit for Ti was 250 mg kg−1. Method means agreed with values assigned by 14–16 laboratories (compatibility indices ≤ 0.49). Under routine conditions, the method would support Ti specifications of ±13.4% relative or wider.

Schlagwörter

Stichwörter der Autor:innen

ICP-OESLiFePO4cathode materialmeasurement uncertaintymethod validationmicrowave digestiontitanium doping

Autor:innen und Institutionen

  • School of Materials Science & Engineering, Gyeongsang National University, Jinju 52828, Republic of Korea.
  • Industry Support Division, Korea Institute of Ceramic Engineering & Technology, Jinju 52851, Republic of Korea.
  • Advanced Materials Technology Division, Korea Testing & Research Institute, Gwacheon 13810, Republic of Korea.

ORCID-Profile: Myung-Gyu Lee, Kyoung-Seok Moon

Förderung

  • Ministry of Trade, Industry and Resources

Zitieren

APA

Lee, M. G., Kim, T. Y., Yi, S. H., Park, J. S., Yoon, Y. J., & Moon, K. S. (2026). Overcoming Incomplete Digestion of Ti-Doped LiFePO4 Cathode Materials: Microwave-Assisted Sample Preparation and Single-Laboratory Validated ICP-OES Determination of Li, Fe, P, and Ti. Molecules, 31(21), 3915. https://doi.org/10.3390/molecules31213915

Vancouver

Lee MG, Kim TY, Yi SH, Park JS, Yoon YJ, Moon KS. Overcoming Incomplete Digestion of Ti-Doped LiFePO4 Cathode Materials: Microwave-Assisted Sample Preparation and Single-Laboratory Validated ICP-OES Determination of Li, Fe, P, and Ti. Molecules. 2026;31(21):3915. doi:10.3390/molecules31213915

BibTeX
@article{Lee2026,
  author = {Lee, Myung-Gyu and Kim, Tae-Young and Yi, Sam-Hang and Park, Joo-Seok and Yoon, Young-Jun and Moon, Kyoung-Seok},
  title = {Overcoming Incomplete Digestion of Ti-Doped LiFePO4 Cathode Materials: Microwave-Assisted Sample Preparation and Single-Laboratory Validated ICP-OES Determination of Li, Fe, P, and Ti},
  journal = {Molecules},
  year = {2026},
  volume = {31},
  number = {21},
  pages = {3915},
  doi = {10.3390/molecules31213915}
}
Kostenlos starten →