EUVIMEDEUVIMED entdecken
Crossref

An instrument-free height readout biosensing device based on gold nanobipyramid-loaded hydrogel for point-of-care detection of acid phosphatase and the BRCA1 gene

Fangqin She, Bin Li, Na Lu

Analytica Chimica Acta · 2026-09 · 1415 · 345681

DOI: 10.1016/j.aca.2026.345681 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-09. Verfasst von Fangqin She und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, Shanghai University of Engineering Science, Shanghai, 201620, China. Hauptthemen laut MEDLINE: Acid Phosphatase, Biosensing Techniques, Genes, BRCA1, Hydrogels. Die Arbeit nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Point-of-care testing (POCT) is crucial for disease diagnosis, especially in resource-limited settings with inadequate laboratory infrastructure. Although visual distance-based readout sensors present a promising approach for instrument-free quantification, their widespread application is hindered by complex fabrication processes and dependence on external driving mechanisms. Here we developed a universal, instrument-free visual quantification platform based on a gold nanobipyramid -loaded agarose (AuNBP/agarose) hydrogel encapsulated in a polycarbonate (PC) tube. The iodine-mediated etching of AuNBPs transduced target recognition into a measurable color-changing hydrogel height. The addition of acid phosphatase (ACP) initiated the enzymatic production of ascorbic acid (AA), driving the etching process and generated a height signal proportional to ACP concentration in the range of 0.1-1000 mU/mL, with a detection limit of 9.72 μU/mL. Moreover, it exhibited high selectivity and satisfactory recoveries for ACP in human serum samples. For DNA detection, target hybridization introduced horseradish peroxidase (HRP), which effectively inhibited etching by consuming H2O2. This strategy enabled sensitive detection of the BRCA1 gene within a concentration range of 100-1500 nM, with a detection limit of 270 nM. Both assays enabled quantitative readout using a simple ruler, without the need for complex instrumentation, demonstrating a universal and cost-effective strategy for POCT detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Acid PhosphataseBiosensing TechniquesGenes, BRCA1HydrogelsMetal NanoparticlesPoint-of-Care SystemsHumansBRCA1 ProteinGoldLimit of Detection

Stichwörter der Autor:innen

Acid phosphataseBRCA1 geneGold nanobipyramidHeight readoutPoint-of-care detection

Substanzen

Acid PhosphataseBRCA1 ProteinBRCA1 protein, humanGoldHydrogels

Autor:innen und Institutionen

  • School of Materials Science and Engineering, Shanghai University of Engineering Science, Shanghai, 201620, China.
  • School of Materials Science and Engineering, Shanghai University of Engineering Science, Shanghai, 201620, China. Electronic address: libin@sues.edu.cn.
  • School of Materials Science and Engineering, Shanghai University of Engineering Science, Shanghai, 201620, China. Electronic address: nlu2014@163.com.

Zitieren

APA

She, F., Li, B., & Lu, N. (2026). An instrument-free height readout biosensing device based on gold nanobipyramid-loaded hydrogel for point-of-care detection of acid phosphatase and the BRCA1 gene. Analytica Chimica Acta, 1415, 345681. https://doi.org/10.1016/j.aca.2026.345681

Vancouver

She F, Li B, Lu N. An instrument-free height readout biosensing device based on gold nanobipyramid-loaded hydrogel for point-of-care detection of acid phosphatase and the BRCA1 gene. Analytica Chimica Acta. 2026;1415:345681. doi:10.1016/j.aca.2026.345681

BibTeX
@article{She2026,
  author = {She, Fangqin and Li, Bin and Lu, Na},
  title = {An instrument-free height readout biosensing device based on gold nanobipyramid-loaded hydrogel for point-of-care detection of acid phosphatase and the BRCA1 gene},
  journal = {Analytica Chimica Acta},
  year = {2026},
  volume = {1415},
  pages = {345681},
  doi = {10.1016/j.aca.2026.345681}
}
Kostenlos starten →