The integration of peptoid and phosphorothioate aptamer into electrochemical biosensors for the robust antifouling detection of prostate-specific antigen in human serum
Analytica Chimica Acta · 2026-07 · 1408 · 345575
DOI: 10.1016/j.aca.2026.345575 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026-07. Verfasst von Yinan Zhan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, State Key Laboratory of Advanced Optical Polymer and Manufac…. Hauptthemen laut MEDLINE: Prostate-Specific Antigen, Biosensing Techniques, Aptamers, Nucleotide, Electrochemical Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Natural Science Foundation of Qingdao Municipality, National Natural Science Foundation of China.
Abstract (Originalsprache)
Electrochemical biosensors for biomarker detection in complex biological media often suffer from performance degradation. Two main causes are non-specific adsorption of biomolecules and enzymolysis of immobilized biomolecules. Consequently, the development of robust antifouling electrochemical biosensors represents an imperative research task. We herein report the design of an electrochemical antifouling biosensor for the detection of prostate-specific antigen (PSA) in complex biofluids based on the peptoid and phosphorothioate aptamer (PS-Apt). The peptoid was designed to be hydrophilic and neutral in total charge, and it was adopted as the antifouling material, while the PS-Apt was used as the biorecognition element. Both the peptoid and the PS-Apt resist degradation by natural enzymes in biofluids such as serum. This ensures the operational stability of the biosensor. The developed biosensor exhibited high sensitivity for PSA detection, with a broad linear range from 1.0 pg/mL to 0.1 μg/mL and a low limit of detection of 0.27 pg/mL. Furthermore, the biosensor demonstrated close agreement with the standard enzyme-linked immunosorbent assay for the quantification of PSA in clinical samples, without suffering from significant biofouling in human serum. This work presents a promising design strategy for robust antifouling biosensors aimed at biomarker monitoring in complex biofluids.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, State Key Laboratory of Advanced Optical Polymer and Manufacturing Technology, College of Chemistry and Molecular Engineering, Qin…
Förderung
- Natural Science Foundation of Qingdao Municipality
- National Natural Science Foundation of China
Zitieren
APA
Zhan, Y., Li, Y., Wang, Y., Yang, J., & Luo, X. (2026). The integration of peptoid and phosphorothioate aptamer into electrochemical biosensors for the robust antifouling detection of prostate-specific antigen in human serum. Analytica Chimica Acta, 1408, 345575. https://doi.org/10.1016/j.aca.2026.345575
Vancouver
Zhan Y, Li Y, Wang Y, Yang J, Luo X. The integration of peptoid and phosphorothioate aptamer into electrochemical biosensors for the robust antifouling detection of prostate-specific antigen in human serum. Analytica Chimica Acta. 2026;1408:345575. doi:10.1016/j.aca.2026.345575
BibTeX
@article{Zhan2026,
author = {Zhan, Yinan and Li, Yanxin and Wang, Yudong and Yang, Jie and Luo, Xiliang},
title = {The integration of peptoid and phosphorothioate aptamer into electrochemical biosensors for the robust antifouling detection of prostate-specific antigen in human serum},
journal = {Analytica Chimica Acta},
year = {2026},
volume = {1408},
pages = {345575},
doi = {10.1016/j.aca.2026.345575}
}
EUVIMED