EUVIMEDEUVIMED entdecken
Crossref

Establishment of a rapid colorimetric sensor for Microcystin-LR based on specific aptamer and positively charged gold nanoparticles

Xueting Cui, Jun Wang, Tingyu Hou, Ming Cai, Luozhao Wang, Yanna Liu, Jinhua Li

Analytica Chimica Acta · 2026

DOI: 10.1016/j.aca.2026.345139 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Xueting Cui und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Public Health, Jilin University, Changchun, Jilin, 130021, China. Hauptthemen laut MEDLINE: Microcystins, Gold, Colorimetry, Metal Nanoparticles. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: Jilin University, Jilin Province Health Commission, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Eutrophication of surface freshwater drinking sources intensifies, leading blue-green algae to release massive microcystins. Microcystin-LR (MC-LR), the most toxic variant, poses severe threats to public health and environmental safety. Conventional MC-LR detection methods rely on bulky, expensive equipment and involve complex, time-consuming sample pretreatment, making them unsuitable for on-site testing. This study developed a colorimetric sensing platform based on the binding of positively charged gold nanoparticles (AuNPs) to MC-LR aptamers for simple and rapid MC-LR detection. Without MC-LR, positively charged gold nanoparticles bind to negatively charged aptamers, aggregate, and turn the solution from yellow to white. This method exhibits high sensitivity (detection limit: 0.1 μg/L) and good specificity (insensitive to interferents like MC-YR and MC-RR), with a total assay time of 55 min, providing a rapid alternative to conventional laboratory-based methods like ELISA. Tests on actual water samples showed recoveries of 96.1-119.8% with relative standard deviations

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrocystinsGoldColorimetryMetal NanoparticlesAptamers, NucleotideBiosensing TechniquesMarine ToxinsLimit of Detection

Stichwörter der Autor:innen

AptamerColorimetricEnvironmental waterMC-LRPositively charged gold nanoparticles

Substanzen

MicrocystinsGoldcyanoginosin LRMarine ToxinsAptamers, Nucleotide

Autor:innen und Institutionen

  • School of Public Health, Jilin University, Changchun, Jilin, 130021, China.
  • State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China. Electronic address: ynliu@rcees.ac.cn.
  • School of Public Health, Jilin University, Changchun, Jilin, 130021, China. Electronic address: jinhua1@jlu.edu.cn.

Förderung

  • Jilin University
  • Jilin Province Health Commission
  • National Natural Science Foundation of China

Zitieren

APA

Cui, X., Wang, J., Hou, T., Cai, M., Wang, L., Liu, Y., & Li, J. (2026). Establishment of a rapid colorimetric sensor for Microcystin-LR based on specific aptamer and positively charged gold nanoparticles. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.345139

Vancouver

Cui X, Wang J, Hou T, Cai M, Wang L, Liu Y, et al. Establishment of a rapid colorimetric sensor for Microcystin-LR based on specific aptamer and positively charged gold nanoparticles. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.345139

BibTeX
@article{Cui2026,
  author = {Cui, Xueting and Wang, Jun and Hou, Tingyu and Cai, Ming and Wang, Luozhao and Liu, Yanna and Li, Jinhua},
  title = {Establishment of a rapid colorimetric sensor for Microcystin-LR based on specific aptamer and positively charged gold nanoparticles},
  journal = {Analytica Chimica Acta},
  year = {2026},
  doi = {10.1016/j.aca.2026.345139}
}
Kostenlos starten →