EUVIMEDEUVIMED entdecken
Crossref

Development of a sandwich ECL aptamer sensor based on self-enhanced Ru(bpy)32+@ Zn-MOF luminophore and PoPD@Au NPs quencher for ultrasensitive EpCAM detection

Xiaoshuo Zhang, Rui Dai, Faqiong Zhao, Baizhao Zeng

Analytica Chimica Acta · 2026

DOI: 10.1016/j.aca.2025.345011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Xiaoshuo Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, Hubei Province, China. Hauptthemen laut MEDLINE: Epithelial Cell Adhesion Molecule, Aptamers, Nucleotide, Electrochemical Techniques, Metal Nanoparticles. Die Arbeit nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Epithelial cell adhesion molecules (EpCAM) protein is one of the most frequently and intensely studied tumor-associated antigens because of its overexpression in most cancer cells. Thus, it is regarded as a tumor biomarker associated with a wide variety of carcinomas and reflects the existence and growth of tumors in the human body. It is highly required to detect low concentrations of EpCAM in early stage for ensuring human health. RESULTS: In this study, a novel sandwich electrochemiluminescence (ECL) aptasensor was developed for EpCAM detection. Wherein oxalate-based Zn-MOF supported tris(2,2'-bipyridyl)ruthenium (II) (Ru(bpy)32+@Zn-MOF) was used as luminophore and gold nanoparticle modified o-phenylenediamine (PoPD@Au NPs) as quencher. The 3D Ru(bpy)32+@Zn-MOF generated self-enhanced ECL without additional co-reactants. Furthermore, it remained stable and had short electron transfer distance, ensuring high and stable ECL signal. The ECL signal could be effectively quenched by PoPD@Au NPs through resonance energy transfer (RET) and electron transfer (ET), due to its absorption spectrum overlapping with the ECL emission spectrum of Ru(bpy)32+@Zn-MOF. In the presence of EpCAM, the aptamer acted as a linker between the luminophore and quencher, forming a sandwich structure that had reduced ECL intensity. Under optimal conditions, EpCAM could be sensitively detected over the range of 1 pg mL-1-100 ng mL-1, with a detection limit of 0.34 pg mL-1. SIGNIFICANCE: This work developed a ECL aptasensor with self-enhanced Ru(bpy)32+@Zn-MOF luminophore for EpCAM detection. The ECL system was simple, but ultrasensitive for EpCAM monitoring, thanks to the ECL-RET and ET between Ru(bpy)32+@Zn-MOF and PoPD@Au NPs. It also could be applied to detect other biomolecules by replacing the aptamer, offering significant potential in disease diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Epithelial Cell Adhesion MoleculeAptamers, NucleotideElectrochemical TechniquesMetal NanoparticlesBiosensing TechniquesPhenylenediaminesMetal-Organic FrameworksGoldHumansZincLuminescent MeasurementsLimit of DetectionOrganometallic Compounds2,2'-Dipyridyl

Stichwörter der Autor:innen

Aptamer sensorElectrochemiluminescenceEpCAMMetal-organic frameworkTris(2,2′-bipyridyl)ruthenium (II)

Substanzen

Epithelial Cell Adhesion MoleculeGoldAptamers, NucleotideZincPhenylenediaminesMetal-Organic FrameworksEPCAM protein, humanOrganometallic Compounds2,2'-Dipyridyl

Autor:innen und Institutionen

  • College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, Hubei Province, China.
  • College of Life Sciences, Wuhan University, Wuhan, 430072, Hubei Province, China.
  • College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, Hubei Province, China. Electronic address: bzzeng@whu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, X., Dai, R., Zhao, F., & Zeng, B. (2026). Development of a sandwich ECL aptamer sensor based on self-enhanced Ru(bpy)32+@ Zn-MOF luminophore and PoPD@Au NPs quencher for ultrasensitive EpCAM detection. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.345011

Vancouver

Zhang X, Dai R, Zhao F, Zeng B. Development of a sandwich ECL aptamer sensor based on self-enhanced Ru(bpy)32+@ Zn-MOF luminophore and PoPD@Au NPs quencher for ultrasensitive EpCAM detection. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2025.345011

BibTeX
@article{Zhang2026,
  author = {Zhang, Xiaoshuo and Dai, Rui and Zhao, Faqiong and Zeng, Baizhao},
  title = {Development of a sandwich ECL aptamer sensor based on self-enhanced Ru(bpy)32+@ Zn-MOF luminophore and PoPD@Au NPs quencher for ultrasensitive EpCAM detection},
  journal = {Analytica Chimica Acta},
  year = {2026},
  doi = {10.1016/j.aca.2025.345011}
}
Kostenlos starten →