Organoid chip based automatic system for long-term quantifying ciliary beating under drug intervention
Analytica Chimica Acta · 2026
DOI: 10.1016/j.aca.2025.344967 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Zixi Li und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, China. Hauptthemen laut MEDLINE: Cilia, Organoids, Lab-On-A-Chip Devices, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Beijing Institute of Technology Research Fund Program for Young Scholars, National High-tech Research and Development Program, National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND: The beating of motile cilia plays an important role in many physiological processes. In recent years, the precise monitoring of ciliary beating has provided valuable insights into cilia-related diseases and their therapies. However, a gap persists between homogeneous in vitro cell models and heterogeneous in vivo ciliary systems. Human-derived ciliary organoids (HDCOs) show promise in bridging this gap but face technical barriers: limited numbers of HDCOs cannot meet multi-well-plate demands, and long-term tracking accuracy is compromised by organoid overlapping/displacement during culture. RESULTS: A multifunctional microfluidic chip (MOCiB-Chip) was developed, featuring a three-layer structure (fluidic layer, porous membrane, capture layer) and two independent regions for multi-concentration experiments. It integrates single-HDCO immobilization, culture, in situ observation, and on-chip drug mixing. Combined with an independently developed analysis program, Ciliary Beating Frequency Analysis Software (CBFAS), and a fluid control module, the automatic quantifying system for ciliary beating (AuCilia) was established. It achieved 7-day monitoring of human bronchial HDCOs and evaluated roflumilast at 0-100 nM: roflumilast at 10 nM increased beating frequency by 81.5 %, 1 nM by 27.8 %, while 100 nM caused cessation by day 2. cAMP measurements confirmed roflumilast's mechanism, validating the system. SIGNIFICANCE: This strategy eliminates HDCO loss via on-chip integration of all procedures, resolving the conflict between limited samples and multi-condition tests. It improves tracking accuracy by avoiding organoid displacement/overlapping, overcoming multi-well-plate limitations. The system's low cost and high reproducibility accelerate drug screening (e.g., roflumilast) and enable precise study of cilia physiology, laying a key technical foundation for cilia-related disease research and clinical translation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, China.
- Department of Thoracic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China; Department of Clinical Nutrition, Peking Union Medical…
- Institute of Clinical Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China; State Key Laboratory of Complex Severe and Rare Diseas…
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China; Department of Biomaterials and Stem Cells, Suzhou Institute of Biom…
- Department of Thoracic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China. Electronic address: pumchnelson@163.com.
- Department of Biomedical Engineering, School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, China. Electronic address: liqin@bit.edu.cn.
Förderung
- Beijing Institute of Technology Research Fund Program for Young Scholars
- National High-tech Research and Development Program
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
- Beijing Institute of Technology
- National Key Laboratory of Science and Technology on Micro/Nano Fabrication
Zitieren
APA
Li, Z., Huang, Z., Wang, D., Li, T., Peng, J., Zhang, A., Sun, R., Wu, X., Zhang, Y., Liang, N., Li, Q., & Wei, Z. (2026). Organoid chip based automatic system for long-term quantifying ciliary beating under drug intervention. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.344967
Vancouver
Li Z, Huang Z, Wang D, Li T, Peng J, Zhang A, et al. Organoid chip based automatic system for long-term quantifying ciliary beating under drug intervention. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2025.344967
BibTeX
@article{Li2026,
author = {Li, Zixi and Huang, Zhicheng and Wang, Daoyun and Li, Tong and Peng, Junya and Zhang, Anlan and Sun, Ruimeng and Wu, Xin and Zhang, Yu and Liang, Naixin and Li, Qin and Wei, Zewen},
title = {Organoid chip based automatic system for long-term quantifying ciliary beating under drug intervention},
journal = {Analytica Chimica Acta},
year = {2026},
doi = {10.1016/j.aca.2025.344967}
}
EUVIMED