MASEA: A microfluidic system for in situ evaluation of tumor angiogenesis in PDO–endothelial co-culture
Biosensors and Bioelectronics · 2026
DOI: 10.1016/j.bios.2026.118565 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Xin Wu und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Lung Neoplasms, Neovascularization, Pathologic, Organoids. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: Fundamental Research Funds for Central Universities of the Central South University, National High-tech Research and Development Program, National Natural Science Foundation of China.
Abstract (Originalsprache)
Patient-derived organoids (PDOs) are promising preclinical models for personalized cancer therapy, but quantitative, time-resolved assessment of PDO-vascular interactions remains difficult. We developed MASEA, an automated microfluidic platform integrating real-time pneumatic fluid control, a PDO culture module, and a custom co-culture/sensing microfluidic chip (MEA-Chip). The system supports perfused PDO-endothelial co-culture in a confined 3D microenvironment and enables in situ measurement of pro-angiogenic factors using a bead-based biosensor, together with standardized image-based quantification of vascular networks. We evaluated MASEA using six lung cancer patient-derived PDO lines co-cultured with HUVECs. Angiogenesis was monitored over 60 h and quantified using total length (TL), number of junctions (NJ), total segment length (TSL), and total mesh area (TMA), while VEGF dynamics were measured in parallel. Across the cohort, co-culture consistently enhanced vascular network formation and increased VEGF levels compared with HUVEC-only controls. Treatment with bevacizumab reduced both angiogenic metrics and VEGF accumulation, demonstrating time-resolved assessment of anti-angiogenic responses. These results establish MASEA as an integrated assay for quantitative analysis of tumor-vascular interactions and for patient-specific screening of anti-angiogenic therapies under controlled microenvironmental conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, China.
- Department of Thoracic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China.
- National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Beijing, 100871, China; School of Integrated Circuits, Peking University, Beijing, 100871, China.
- Department of Pulmonary and Critical Care Medicine, Emergency General Hospital, Beijing, China.
- Department of Clinical Nutrition, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
- Department of Thoracic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100730, China. Electronic address: pumchnelson@163.com.
Förderung
- Fundamental Research Funds for Central Universities of the Central South University
- National High-tech Research and Development Program
- National Natural Science Foundation of China
- Beijing Institute of Technology Research Fund Program for Young Scholars
- Beijing Institute of Technology
- National Key Laboratory of Science and Technology on Micro/Nano Fabrication
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Wu, X., Wang, D., Gao, M., Qin, Y., Huang, Z., Zheng, Z., Gao, C., Lin, Y., Wang, Z., Yu, K., Liang, N., Zhang, N., & Wei, Z. (2026). MASEA: A microfluidic system for in situ evaluation of tumor angiogenesis in PDO–endothelial co-culture. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118565
Vancouver
Wu X, Wang D, Gao M, Qin Y, Huang Z, Zheng Z, et al. MASEA: A microfluidic system for in situ evaluation of tumor angiogenesis in PDO–endothelial co-culture. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118565
BibTeX
@article{Wu2026,
author = {Wu, Xin and Wang, Daoyun and Gao, Mingyao and Qin, Yuzhi and Huang, Zhicheng and Zheng, Zhibo and Gao, Chao and Lin, Yuxiao and Wang, Zhina and Yu, Kang and Liang, Naixin and Zhang, Nan and Wei, Zewen},
title = {MASEA: A microfluidic system for in situ evaluation of tumor angiogenesis in PDO–endothelial co-culture},
journal = {Biosensors and Bioelectronics},
year = {2026},
doi = {10.1016/j.bios.2026.118565}
}
EUVIMED