Selective detection of Escherichia coli based on BSA/CNTs/ UIO-66-NH2 molecularly imprinted electrochemical sensors
Analytica Chimica Acta · 2025-12 · 1377 · 344644
DOI: 10.1016/j.aca.2025.344644 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-12. Verfasst von Jiaqi Niu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Marine Engineering College, Dalian Maritime University, Dalian, 116026, PR China. Hauptthemen laut MEDLINE: Electrochemical Techniques, Escherichia coli, Molecular Imprinting, Nanotubes, Carbon. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Dalian Maritime University, Ministry of Industry and Information Technology of the People's Republic of China.
Abstract (Originalsprache)
As a common contaminating bacterium, Escherichia coli (E. coli) has caused severe harm in various fields such as food, healthcare, and the environment. Traditional detection methods for Escherichia coli, owing to factors like high cost and low efficiency, are unable to meet the detection requirements at the present stage. Therefore, the development of a simple, rapid, and highly efficient detection method for Escherichia coli represents an urgent issue that needs to be addressed promptly. This study focused on the development of a highly selective molecularly imprinted electrochemical sensor for E. coli. Molecularly imprinted polymers (MIPs) were prepared by electropolymerization on the surface of glassy carbon electrode using o-phenylenediamine as the functional monomer, aminated metal-organic frameworks (MOFs) and carbon nanotubes (CNTs) as the composites, and bovine serum albumin (BSA) was added into the polymer film to attenuate the non-imprinting effect. The linear range of the sensor was 10-107 CFU/mL and the detection limit was 5.2 CFU/mL. Good recovery rates were shown in real samples of drinking water, milk and orange juice. In addition, the good binding ability of the E. coli template molecule to the functional monomer o-phenylenediamine was verified by molecular docking and molecular dynamics (MD) simulations. This study was able to detect E. coli in 20 min, which provides a more open idea for the application of rapid detection of E. coli on-site, as well as the construction of molecularly imprinted electrochemical sensors and the analysis of the binding mechanism between template molecules and functional monomers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Marine Engineering College, Dalian Maritime University, Dalian, 116026, PR China.
- Marine Engineering College, Dalian Maritime University, Dalian, 116026, PR China; Engineering Technology Center for Ship Safety and Pollution Control, Liaoning Province, Dalian, 116026, PR China. Electronic address: wuw…
Förderung
- National Natural Science Foundation of China
- Dalian Maritime University
- Ministry of Industry and Information Technology of the People's Republic of China
Zitieren
APA
Niu, J., Liu, J., Guo, P., Du, M., Wu, W., Zhang, Z., Ning, Y., Zhou, D., & Cao, H. (2025). Selective detection of Escherichia coli based on BSA/CNTs/ UIO-66-NH2 molecularly imprinted electrochemical sensors. Analytica Chimica Acta, 1377, 344644. https://doi.org/10.1016/j.aca.2025.344644
Vancouver
Niu J, Liu J, Guo P, Du M, Wu W, Zhang Z, et al. Selective detection of Escherichia coli based on BSA/CNTs/ UIO-66-NH2 molecularly imprinted electrochemical sensors. Analytica Chimica Acta. 2025;1377:344644. doi:10.1016/j.aca.2025.344644
BibTeX
@article{Niu2025,
author = {Niu, Jiaqi and Liu, Jinhui and Guo, Ping and Du, Min and Wu, Wanqing and Zhang, Ziyang and Ning, Ye and Zhou, Dedi and Cao, Haidong},
title = {Selective detection of Escherichia coli based on BSA/CNTs/ UIO-66-NH2 molecularly imprinted electrochemical sensors},
journal = {Analytica Chimica Acta},
year = {2025},
volume = {1377},
pages = {344644},
doi = {10.1016/j.aca.2025.344644}
}
EUVIMED