EUVIMEDEUVIMED entdecken
Crossref

Ultra-sensitive electrochemical sensor based on molecularly imprinted polydopamine grafted with MWCNT-COOH for tryptophan detection

Habib Razmi iD, Fatemeh Maleki, Behnaz Saedi

Microchimica Acta · 2025-08 · 192 (8)

DOI: 10.1007/s00604-025-07329-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 21.07.2025. Verfasst von Habib Razmi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, Tabriz, 53714-161, Iran. mh_razmi@yahoo.com. Hauptthemen laut MEDLINE: Tryptophan, Indoles, Nanotubes, Carbon, Polymers. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 71 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An electrochemical sensing platform was developed for the detection of tryptophan (Trp) using a molecularly imprinted polydopamine grafted with functionalized multi-walled carbon nanotubes (MWCNTs) modified glassy carbon electrode (GCE), referred to as MWCNT-COOH/PDA-MIP. Dopamine, as a monomer, underwent self-polymerization in the presence of MWCNT-COOH and the target molecule, Trp, forming a polydopamine network. The synthesized composite was dispersed in an aqueous solvent and cast onto the GCE surface. Trp was then removed from the polymer matrix, creating molecularly imprinted cavities tailored to the size and properties of the target molecule. These cavities enabled the MWCNT-COOH/PDA-MIP to adsorb and recognize Trp with high precision and selectivity. This novel electrochemical sensor achieves an ultra-low detection limit and enhanced specificity for tryptophan detection through the integration of molecularly imprinted polydopamine with functionalized MWCNTs. The morphology and composition of the prepared sensor were analyzed by FT-IR, XRD, EDX, and SEM techniques. Sensor performance was evaluated using differential pulse voltammetry (DPV), revealing a linear response over two concentration ranges: 10-14 to 10-9 M and 10-8 to 10-4 M. The limit of detection (LOD) and limit of quantification (LOQ) were 4.33 × 10-15 M and 14.43 × 10-15 M, respectively. The sensor was successfully applied to measure Trp in real samples, including blood serum and milk, achieving satisfactory results with an average recovery of 97.15%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TryptophanIndolesNanotubes, CarbonPolymersElectrochemical TechniquesMolecularly Imprinted PolymersMolecular ImprintingLimit of DetectionElectrodesAnimals

Stichwörter der Autor:innen

Differential pulse voltammetryElectrochemical sensorMWCNT-COOHModified glassy carbon electrodeMolecularly imprinted polymer (MIP)PolydopamineTryptophan detection

Substanzen

TryptophanpolydopamineIndolesNanotubes, CarbonPolymersMolecularly Imprinted Polymers

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, Tabriz, 53714-161, Iran. mh_razmi@yahoo.com.
  • Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, Tabriz, 53714-161, Iran.

ORCID-Profile: Habib Razmi

Zitieren

APA

Razmi, H., Maleki, F., & Saedi, B. (2025). Ultra-sensitive electrochemical sensor based on molecularly imprinted polydopamine grafted with MWCNT-COOH for tryptophan detection. Microchimica Acta, 192(8). https://doi.org/10.1007/s00604-025-07329-0

Vancouver

Razmi H, Maleki F, Saedi B. Ultra-sensitive electrochemical sensor based on molecularly imprinted polydopamine grafted with MWCNT-COOH for tryptophan detection. Microchimica Acta. 2025;192(8). doi:10.1007/s00604-025-07329-0

BibTeX
@article{Razmi2025,
  author = {Razmi, Habib and Maleki, Fatemeh and Saedi, Behnaz},
  title = {Ultra-sensitive electrochemical sensor based on molecularly imprinted polydopamine grafted with MWCNT-COOH for tryptophan detection},
  journal = {Microchimica Acta},
  year = {2025},
  volume = {192},
  number = {8},
  doi = {10.1007/s00604-025-07329-0}
}
Kostenlos starten →