EUVIMEDEUVIMED entdecken
Crossref

Enzymatic hydrolysis combined with chemiluminescence immunoassay: Foresight for automated and rapid urinary aldosterone detection

Jian Zhong, Honglei Li, Yicong Yin, Wei Luo, Xiuzhi Guo, Danchen Wang, Songlin Yu, Ling Qiu

Analytica Chimica Acta · 2025

DOI: 10.1016/j.aca.2025.344403 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025. Verfasst von Jian Zhong und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing…. Hauptthemen laut MEDLINE: Aldosterone, Luminescent Measurements, Glucuronidase. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Beijing Natural Science Foundation, Ministry of Science and Technology of the People's Republic of China, Chinese Academy of Medical Sciences & Peking Union Medical College.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The 24-hour urinary aldosterone test offers superior stability in assessing aldosterone secretion compared to single-point plasma measurements, suggesting its potential utility as a diagnostic tool for primary aldosteronism. However, its clinical utility is hampered by labor-intensive manual urine treatment and the lack of diagnostic cut-off, with the former demonstrating considerable inter-laboratory variability. There is an urgent need for an automated assay to facilitate rapid and standardized 24-hour urinary aldosterone testing, accompanied by method-specific diagnostic cut-offs. RESULTS: The systematic comparison of hydrolysis methodologies (hydrochloric acid, biogenic enzymes, and transgenic enzymes) reveals that IMCS-RT transgenic β-glucuronidase exhibits the highest efficiency, achieving complete hydrolysis within 30 min at room temperature (∼25 °C). Based on this, an automated chemiluminescence system is developed, integrating rapid enzymatic hydrolysis, antibody-mediated aldosterone capture, magnetic separation, and luminous reactions. It demonstrates excellent linearity (0.030-10.00 ng/mL, R2 = 0.996) and a clinically reportable range of 0.030-40.00 ng/mL. The measured aldosterone levels strongly correlate with those obtained via liquid chromatography-tandem mass spectrometry following acid hydrolysis (r = 0.9836) and enzymatic hydrolysis (r = 0.9846). Using samples from 85 patients with primary aldosteronism and 187 controls, we establish a diagnostic cut-off of 15.28 μg/24h, yielding an area under the curve of 0.80, a sensitivity of 0.776, and a specificity of 0.706. SIGNIFICANCE: This study presents an automated chemiluminescence immunoassay system incorporating transgenic β-glucuronidase-mediated hydrolysis for rapid and reliable quantification of 24-hour urinary aldosterone. Method-specific diagnostic cut-offs further augment the clinical utility of this assay, offering a non-invasive diagnostic approach to primary aldosteronism.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AldosteroneLuminescent MeasurementsGlucuronidaseHumansHydrolysisImmunoassayAutomationHyperaldosteronism

Stichwörter der Autor:innen

AldosteroneAutomationChemiluminescent immunoassayCut-offGlucuronidaseLC-MS/MSPrimary aldosteronismUrine

Substanzen

AldosteroneGlucuronidase

Autor:innen und Institutionen

  • Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: 13278883810@163.com.
  • Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: 461175192@qq.com.
  • Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: yicongyincream@163.com.
  • Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: luowei0314@163.com.
  • Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: xiuzhi06@163.com.
  • Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: 895492905@qq.com.

Förderung

  • Beijing Natural Science Foundation
  • Ministry of Science and Technology of the People's Republic of China
  • Chinese Academy of Medical Sciences & Peking Union Medical College

Zitieren

APA

Zhong, J., Li, H., Yin, Y., Luo, W., Guo, X., Wang, D., Yu, S., & Qiu, L. (2025). Enzymatic hydrolysis combined with chemiluminescence immunoassay: Foresight for automated and rapid urinary aldosterone detection. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.344403

Vancouver

Zhong J, Li H, Yin Y, Luo W, Guo X, Wang D, et al. Enzymatic hydrolysis combined with chemiluminescence immunoassay: Foresight for automated and rapid urinary aldosterone detection. Analytica Chimica Acta. 2025. doi:10.1016/j.aca.2025.344403

BibTeX
@article{Zhong2025,
  author = {Zhong, Jian and Li, Honglei and Yin, Yicong and Luo, Wei and Guo, Xiuzhi and Wang, Danchen and Yu, Songlin and Qiu, Ling},
  title = {Enzymatic hydrolysis combined with chemiluminescence immunoassay: Foresight for automated and rapid urinary aldosterone detection},
  journal = {Analytica Chimica Acta},
  year = {2025},
  doi = {10.1016/j.aca.2025.344403}
}
Kostenlos starten →