Enzymatic hydrolysis combined with chemiluminescence immunoassay: Foresight for automated and rapid urinary aldosterone detection
Analytica Chimica Acta · 2025
DOI: 10.1016/j.aca.2025.344403 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025. Verfasst von Jian Zhong und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing…. Hauptthemen laut MEDLINE: Aldosterone, Luminescent Measurements, Glucuronidase. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Beijing Natural Science Foundation, Ministry of Science and Technology of the People's Republic of China, Chinese Academy of Medical Sciences & Peking Union Medical College.
Abstract (Originalsprache)
BACKGROUND: The 24-hour urinary aldosterone test offers superior stability in assessing aldosterone secretion compared to single-point plasma measurements, suggesting its potential utility as a diagnostic tool for primary aldosteronism. However, its clinical utility is hampered by labor-intensive manual urine treatment and the lack of diagnostic cut-off, with the former demonstrating considerable inter-laboratory variability. There is an urgent need for an automated assay to facilitate rapid and standardized 24-hour urinary aldosterone testing, accompanied by method-specific diagnostic cut-offs. RESULTS: The systematic comparison of hydrolysis methodologies (hydrochloric acid, biogenic enzymes, and transgenic enzymes) reveals that IMCS-RT transgenic β-glucuronidase exhibits the highest efficiency, achieving complete hydrolysis within 30 min at room temperature (∼25 °C). Based on this, an automated chemiluminescence system is developed, integrating rapid enzymatic hydrolysis, antibody-mediated aldosterone capture, magnetic separation, and luminous reactions. It demonstrates excellent linearity (0.030-10.00 ng/mL, R2 = 0.996) and a clinically reportable range of 0.030-40.00 ng/mL. The measured aldosterone levels strongly correlate with those obtained via liquid chromatography-tandem mass spectrometry following acid hydrolysis (r = 0.9836) and enzymatic hydrolysis (r = 0.9846). Using samples from 85 patients with primary aldosteronism and 187 controls, we establish a diagnostic cut-off of 15.28 μg/24h, yielding an area under the curve of 0.80, a sensitivity of 0.776, and a specificity of 0.706. SIGNIFICANCE: This study presents an automated chemiluminescence immunoassay system incorporating transgenic β-glucuronidase-mediated hydrolysis for rapid and reliable quantification of 24-hour urinary aldosterone. Method-specific diagnostic cut-offs further augment the clinical utility of this assay, offering a non-invasive diagnostic approach to primary aldosteronism.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: 13278883810@163.com.
- Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: 461175192@qq.com.
- Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: yicongyincream@163.com.
- Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: luowei0314@163.com.
- Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: xiuzhi06@163.com.
- Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, 100730, China. Electronic address: 895492905@qq.com.
Förderung
- Beijing Natural Science Foundation
- Ministry of Science and Technology of the People's Republic of China
- Chinese Academy of Medical Sciences & Peking Union Medical College
Zitieren
APA
Zhong, J., Li, H., Yin, Y., Luo, W., Guo, X., Wang, D., Yu, S., & Qiu, L. (2025). Enzymatic hydrolysis combined with chemiluminescence immunoassay: Foresight for automated and rapid urinary aldosterone detection. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.344403
Vancouver
Zhong J, Li H, Yin Y, Luo W, Guo X, Wang D, et al. Enzymatic hydrolysis combined with chemiluminescence immunoassay: Foresight for automated and rapid urinary aldosterone detection. Analytica Chimica Acta. 2025. doi:10.1016/j.aca.2025.344403
BibTeX
@article{Zhong2025,
author = {Zhong, Jian and Li, Honglei and Yin, Yicong and Luo, Wei and Guo, Xiuzhi and Wang, Danchen and Yu, Songlin and Qiu, Ling},
title = {Enzymatic hydrolysis combined with chemiluminescence immunoassay: Foresight for automated and rapid urinary aldosterone detection},
journal = {Analytica Chimica Acta},
year = {2025},
doi = {10.1016/j.aca.2025.344403}
}