EUVIMEDEUVIMED entdecken
Multizentrische Studie

An innovative immunoassay for accurate aldosterone quantification: overcoming low-level inaccuracy and renal dysfunction-associated interference

Kaijuan Wang iD, Hongying Cong, Zhangwei Gao, Xiaojing Gao, Wei Zhang, Xiaocui Shi, Zhou Zhou

Clinical Chemistry and Laboratory Medicine (CCLM) · 2025

DOI: 10.1515/cclm-2025-0743 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Clinical Chemistry and Laboratory Medicine (CCLM), 2025. Verfasst von Kaijuan Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center of Laboratory Medicine, Beijing Key Laboratory of Cardiovascular Disease Warning and Diagnosis, National Clinical Research Center for Cardiova…. Hauptthemen laut MEDLINE: Aldosterone, Renal Insufficiency, Chronic. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben. Gefördert von: CAMS Innovation Fund for Medical Sciences, Noncommunicable Chronic Diseases-National Science and Technology Major Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Accurate quantification of aldosterone is critical for screening and diagnosing primary aldosteronism (PA). Current competitive chemiluminescence immunoassays (cCLIA) overestimate plasma aldosterone concentration (PAC) compared to liquid chromatography-tandem mass spectrometry (LC-MS/MS). However, LC-MS/MS is technically demanding and time-consuming, limiting its widespread clinical utility. Therefore, a novel two-step sandwich chemiluminescence immunoassay (sCLIA) for accurate quantification of PAC was systematically evaluated.

Methods

Precision, trueness, linear range, and maximum dilution factor of the new immunoassay were comprehensively validated. In a multicenter study involving 2,696 samples from seven Chinese centers, PAC measurements were performed in parallel using sCLIA, cCLIA, and LC-MS/MS. The study specifically focused on evaluating the assay’s performance at low aldosterone concentrations and in patients with chronic kidney disease (CKD), investigating potential interference from renal impairment by comparing the consistency between immunoassays and LC-MS/MS results across different CKD stages.

Results

The sCLIA exhibited excellent analytical performance for PAC measurement, with intra-assay imprecision

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AldosteroneRenal Insufficiency, ChronicHumansImmunoassayTandem Mass SpectrometryChromatography, LiquidHyperaldosteronismMaleFemaleMiddle AgedLuminescent MeasurementsLimit of DetectionAdult

Stichwörter der Autor:innen

LC-MS/MSaldosteronechronic kidney diseaseinterferenceprimary aldosteronismsandwich chemiluminescent immunoassay

Substanzen

Aldosterone

Autor:innen und Institutionen

  • Center of Laboratory Medicine, Beijing Key Laboratory of Cardiovascular Disease Warning and Diagnosis, National Clinical Research Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences &…

ORCID-Profile: Kaijuan Wang

Förderung

  • CAMS Innovation Fund for Medical Sciences
  • Noncommunicable Chronic Diseases-National Science and Technology Major Project

Zitieren

APA

Wang, K., Cong, H., Gao, Z., Gao, X., Zhang, W., Shi, X., & Zhou, Z. (2025). An innovative immunoassay for accurate aldosterone quantification: overcoming low-level inaccuracy and renal dysfunction-associated interference. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2025-0743

Vancouver

Wang K, Cong H, Gao Z, Gao X, Zhang W, Shi X, et al. An innovative immunoassay for accurate aldosterone quantification: overcoming low-level inaccuracy and renal dysfunction-associated interference. Clinical Chemistry and Laboratory Medicine (CCLM). 2025. doi:10.1515/cclm-2025-0743

BibTeX
@article{Wang2025,
  author = {Wang, Kaijuan and Cong, Hongying and Gao, Zhangwei and Gao, Xiaojing and Zhang, Wei and Shi, Xiaocui and Zhou, Zhou},
  title = {An innovative immunoassay for accurate aldosterone quantification: overcoming low-level inaccuracy and renal dysfunction-associated interference},
  journal = {Clinical Chemistry and Laboratory Medicine (CCLM)},
  year = {2025},
  doi = {10.1515/cclm-2025-0743}
}
Kostenlos starten →