EUVIMEDEUVIMED entdecken
Crossref

Boric acid-functionalized PANI-ABA/PA hydrogel-based flexible pH sensor for real-time sweat monitoring

Meihui Gao, Xianjing Zhang, Shiqi Li, He Gao, Xinyu Li, Dongyuan Xu, Longbin Xu

Analytica Chimica Acta · 2025

DOI: 10.1016/j.aca.2025.344188 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025. Verfasst von Meihui Gao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, College of Science, Yanbian University, Yanji, Jilin, 133002, PR China. Hauptthemen laut MEDLINE: Boric Acids, Sweat, Hydrogels, Aniline Compounds. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Yanbian University, Department of Science and Technology of Jilin Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Wearable pH sensors have emerged as promising tools for real-time health monitoring, particularly for sports and clinical applications, due to their ability to monitor key physiological indicators such as sweat pH. Sweat analysis provides valuable insights into metabolic processes and physical exertion. However, the development of flexible, stable, and highly sensitive sensors for accurate sweat pH detection remains a challenge. Conductive polymer such as polyaniline (PANI), have gained attention due to their unique properties, but further improvements in mechanical flexibility and sensor performance are needed to fully realize their potential for wearable biosensing applications. RESULTS: We present a boric acid-functionalized PANI-ABA/PA hydrogel, synthesized via electrochemical deposition, where boric acid plays a crucial role in crosslinking the rigid PANI material into a flexible, porous grid structure. This crosslinking improves the mechanical properties of the hydrogel while enhancing its ion-exchange capacity, leading to greater sensitivity and selectivity for H+ ions. PANI-ABA/PA hydrogel exhibits super-Nernstian behavior (77.80 mV pH-1) across the physiological pH range (3.00-10.00), with rapid response times, minimal temperature drift, and excellent repeatability. Moreover, the hydrogel exhibits outstanding antifouling properties, ensuring consistent performance even in dynamic environments. Real-time human subject testing confirms the sensor's ability to accurately monitor sweat pH during physical activity, providing reliable and real-time data. These results highlight the promising potential of the PANI-based hydrogel for wearable biosensors in health monitoring. SIGNIFICANCE AND NOVELTY: This study highlights the role of boric acid in facilitating the formation of a crosslinked PANI-based grid structure, which improves the sensor's performance in wearable applications. Enhanced sensitivity, stability, and mechanical flexibility make this smart wearable sensor a promising candidate for continuous, non-invasive health monitoring. It opens new opportunities for real-time athletic performance tracking, personalized healthcare, and disease diagnostics, positioning it as a leading technology for future wearable health-monitoring systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Boric AcidsSweatHydrogelsAniline CompoundsBiosensing TechniquesHydrogen-Ion ConcentrationHumansWearable Electronic DevicesElectrochemical Techniques

Stichwörter der Autor:innen

Boric acid functionalizationPANI/PA hydrogelSweat monitoringWearable biosensorpH sensor

Substanzen

Boric Acidsboric acidHydrogelspolyanilineAniline Compounds

Autor:innen und Institutionen

  • Department of Chemistry, College of Science, Yanbian University, Yanji, Jilin, 133002, PR China.
  • Key Laboratory of Cellular Function and Pharmacology of Jilin Province, Yanbian University, Yanji, 133002, PR China.
  • Department of Polymer Materials and Engineering, College of Engineering, Yanbian University, Yanji, 133002, PR China.
  • Department of Polymer Materials and Engineering, College of Engineering, Yanbian University, Yanji, 133002, PR China. Electronic address: xinyuli@ybu.edu.cn.
  • Department of Chemistry, College of Science, Yanbian University, Yanji, Jilin, 133002, PR China. Electronic address: longbinx@ybu.edu.cn.

Förderung

  • Yanbian University
  • Department of Science and Technology of Jilin Province

Zitieren

APA

Gao, M., Zhang, X., Li, S., Gao, H., Li, X., Xu, D., & Xu, L. (2025). Boric acid-functionalized PANI-ABA/PA hydrogel-based flexible pH sensor for real-time sweat monitoring. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.344188

Vancouver

Gao M, Zhang X, Li S, Gao H, Li X, Xu D, et al. Boric acid-functionalized PANI-ABA/PA hydrogel-based flexible pH sensor for real-time sweat monitoring. Analytica Chimica Acta. 2025. doi:10.1016/j.aca.2025.344188

BibTeX
@article{Gao2025,
  author = {Gao, Meihui and Zhang, Xianjing and Li, Shiqi and Gao, He and Li, Xinyu and Xu, Dongyuan and Xu, Longbin},
  title = {Boric acid-functionalized PANI-ABA/PA hydrogel-based flexible pH sensor for real-time sweat monitoring},
  journal = {Analytica Chimica Acta},
  year = {2025},
  doi = {10.1016/j.aca.2025.344188}
}
Kostenlos starten →