High accuracy sensor for two-parameter detection of adrenaline and pH in sweat
Biosensors and Bioelectronics · 2025-11 · 287 · 117675
DOI: 10.1016/j.bios.2025.117675 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-11. Verfasst von Zhenjie Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Future, School of Automation, Shandong Key Laboratory of Industrial ControlTechnology, Qingdao University, Qingdao, 266071, China. Hauptthemen laut MEDLINE: Sweat, Biosensing Techniques, Wearable Electronic Devices, Epinephrine. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Natural Science Foundation of Shandong Province, Qingdao Postdoctoral Science Foundation.
Abstract (Originalsprache)
Here, we report a wearable device integrating a sweat collection unit and a molecularly imprinted polymer (MIP) - based sensor for the non-invasive detection of adrenaline (AD). In this paper, a new MIP method is proposed, which uses AD molecule as template, and electropolymerizes aniline and 3-aminophenylboronic acid (3-APBA) to form molecular imprinting. Surface modifications, incorporating carbon nanotubes (CNT) and MIP optimization, enhanced the device's specific surface area by 166.45 % (±2.82 %), yielding a wide linear detection range of AD (10-6 μmol L-1 to 103 μmol L-1). In this study, a three-dimensional response model was constructed by analyzing the current values corresponding to sweat pH levels (4.0-8.0) and AD concentrations, enabling a linear response and accurate prediction of AD levels in sweat. The integrated flexible electronic platform supports real-time data transmission via Bluetooth or NFC to a mobile application, facilitating efficient detection. Comprehensive integration and validation, including artificial sweat testing and correlation with ELISA results, underscore the sensor's potential as a robust and versatile solution for wearable health monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute for Future, School of Automation, Shandong Key Laboratory of Industrial ControlTechnology, Qingdao University, Qingdao, 266071, China.
- Department of Visceral and Transplant, University Hospital Zurich, Zurich, 8091, Switzerland; University of Zurich, 8006, Zürich, Switzerland.
- School of medical sciences, University of Sydney, Australia.
- College of Engineering, Zhejiang University, China.
- The Affiliated Hospital of Qingdao University, Qingdao, 266071, China.
- Suzhou Institute of Biomedical Engineering and Technology, Chinese.Academy of Sciences, Suzhou, 215163, China.
Förderung
- Natural Science Foundation of Shandong Province
- Qingdao Postdoctoral Science Foundation
Zitieren
APA
Zhang, Z., Wei, W., Li, A. A., Wang, C., Tang, C., Wang, Q., Zhou, L., & Kong, H. (2025). High accuracy sensor for two-parameter detection of adrenaline and pH in sweat. Biosensors and Bioelectronics, 287, 117675. https://doi.org/10.1016/j.bios.2025.117675
Vancouver
Zhang Z, Wei W, Li AA, Wang C, Tang C, Wang Q, et al. High accuracy sensor for two-parameter detection of adrenaline and pH in sweat. Biosensors and Bioelectronics. 2025;287:117675. doi:10.1016/j.bios.2025.117675
BibTeX
@article{Zhang2025,
author = {Zhang, Zhenjie and Wei, Wei and Li, Anne Ailina and Wang, Chenhao and Tang, Chengchen and Wang, Qing and Zhou, Lianqun and Kong, Hui},
title = {High accuracy sensor for two-parameter detection of adrenaline and pH in sweat},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {287},
pages = {117675},
doi = {10.1016/j.bios.2025.117675}
}
EUVIMED