EUVIMEDEUVIMED entdecken
Crossref

Construction of a molecularly imprinted electroluminescence sensor for pyrimethanil detection via dummy template imprinting combined with click-chemical labeling of mimic enzymes

Lijuan Lin, Peng Gao, Minjin Wu, Kui Luo, Jianping Li

Analytica Chimica Acta · 2025

DOI: 10.1016/j.aca.2025.344169 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025. Verfasst von Lijuan Lin und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, 541004, China. Hauptthemen laut MEDLINE: Molecularly Imprinted Polymers, Pyrimidines, Molecular Imprinting, Electrochemical Techniques. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Molecularly imprinted polymer (MIP) sensors have been used to detect trace amounts of pesticide residues. But the difficulty of inert analytes in producing measurable signals often limits the application of MIP sensors. The inherent limitations of the signal transduction mechanism impose fundamental constraints on the enhancement of detection sensitivity. RESULTS: Herein, a strategy was proposed for sensitive, selective and rapid determination of trace pyrimethanil (PMT) residues using MIP sensors by the aid of dummy template imprinting. MIP film was synthesized using vinyl pyrimethanil (Abbr. PMT-Vi), a structural analogue of PMT, as the dummy template molecule. After the formation of MIP film, analyte PMT was added for competing with PMT-Vi in the imprinted cavities of MIP. Then, Fe/N-PAMAM-SH, a dendritic polymer bound with Fe/N CDs, was immobilized onto the MIP via the Thiol-ene click reaction between Fe/N-PAMAM-SH and PMT-Vi. PMT was indirectly determined by measuring the ECL signal of Fe/N CDs in the luminol-hydrogen peroxide system. SIGNIFICANCE: The strategy greatly enhances the detection sensitivity of MIP sensors, achieving a detection limit of 2.58 × 10-16 mol/L. It also offers a novel approach for detecting molecules that lack characteristic signals or generate weak signals.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Molecularly Imprinted PolymersPyrimidinesMolecular ImprintingElectrochemical TechniquesLuminescent MeasurementsClick ChemistryLimit of Detection

Stichwörter der Autor:innen

Click-chemistryDummy templateMimic enzymesMolecularly imprinted sensorPesticide residue

Substanzen

Molecularly Imprinted PolymerspyrimethanilPyrimidines

Autor:innen und Institutionen

  • College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, 541004, China.
  • College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, 541004, China. Electronic address: likianping@263.net.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Lin, L., Gao, P., Wu, M., Luo, K., & Li, J. (2025). Construction of a molecularly imprinted electroluminescence sensor for pyrimethanil detection via dummy template imprinting combined with click-chemical labeling of mimic enzymes. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.344169

Vancouver

Lin L, Gao P, Wu M, Luo K, Li J. Construction of a molecularly imprinted electroluminescence sensor for pyrimethanil detection via dummy template imprinting combined with click-chemical labeling of mimic enzymes. Analytica Chimica Acta. 2025. doi:10.1016/j.aca.2025.344169

BibTeX
@article{Lin2025,
  author = {Lin, Lijuan and Gao, Peng and Wu, Minjin and Luo, Kui and Li, Jianping},
  title = {Construction of a molecularly imprinted electroluminescence sensor for pyrimethanil detection via dummy template imprinting combined with click-chemical labeling of mimic enzymes},
  journal = {Analytica Chimica Acta},
  year = {2025},
  doi = {10.1016/j.aca.2025.344169}
}
Kostenlos starten →