Molecularly Imprinted Polymer-Based Electrogenerated Chemiluminescence Sensor for Sensitive and Selective Fentanyl Detection
Analytical Chemistry · 2026
DOI: 10.1021/acs.analchem.5c06407 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Arati Biswakarma und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, The University of Southern Mississippi, Hattiesburg, Mississippi 39406, United States. Hauptthemen laut MEDLINE: Fentanyl, Molecularly Imprinted Polymers, Luminescent Measurements, Electrochemical Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. Department of Defense.
Abstract (Originalsprache)
The escalating prevalence of fentanyl, a highly potent synthetic opioid responsible for rising overdose fatalities and public health crises, underscores the critical need for sensitive and selective detection methodologies. Herein, we report a molecularly imprinted polymer (MIP)-based electrogenerated chemiluminescence (ECL) sensor for ultrasensitive and selective quantification of fentanyl. The sensor was fabricated by electropolymerizing 4-aminobenzoic acid (4-ABA) on a glassy carbon electrode (GCE) in the presence of fentanyl as the template, followed by template elution to yield recognition nanocavities within the MIP film. ECL signal transduction was achieved through the anodic coreactant pathway, wherein fentanyl (as the coreactant) bound within the MIP cavities reacted with solution-phase [Ru(bpy)3]2+ (as the ECL emitter) in phosphate buffer (pH 7.5) during anodic scans from 0 to 1.60 V vs Ag/AgCl (3.0 M KCl). Critical fabrication and operational parameters, including electropolymerization cycles, template concentration and molar ratio to the monomer, elution conditions, and rebinding duration, were systematically optimized. Density functional theory and density of states investigations guided elution solvent selection and elucidated favorable fentanyl-polymer interactions, verifying the sensor's specificity toward fentanyl over five common structurally similar interferents. Under optimized conditions, the MIP-ECL sensor exhibited a limit of detection of ∼1 μM (S/N = 3), equivalent to 3.4 ng of fentanyl using 10 μL solution, with three distinctive linear regions spanning 1.0 to 6.0, 6.0 to 40.0, and 40.0 to 70.0 μM. Additionally, the sensor demonstrated high reproducibility and stability, positioning it as a promising platform for rapid forensic analysis of illicit fentanyl.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Biochemistry, The University of Southern Mississippi, Hattiesburg, Mississippi 39406, United States.
ORCID-Profile: Wujian Miao
Förderung
- U.S. Department of Defense
Zitieren
APA
Biswakarma, A., & Miao, W. (2026). Molecularly Imprinted Polymer-Based Electrogenerated Chemiluminescence Sensor for Sensitive and Selective Fentanyl Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c06407
Vancouver
Biswakarma A, Miao W. Molecularly Imprinted Polymer-Based Electrogenerated Chemiluminescence Sensor for Sensitive and Selective Fentanyl Detection. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.5c06407
BibTeX
@article{Biswakarma2026,
author = {Biswakarma, Arati and Miao, Wujian},
title = {Molecularly Imprinted Polymer-Based Electrogenerated Chemiluminescence Sensor for Sensitive and Selective Fentanyl Detection},
journal = {Analytical Chemistry},
year = {2026},
doi = {10.1021/acs.analchem.5c06407}
}
EUVIMED