MWCNTs/PANI silk fibroin film sensor based on microneedle array for sweat pH detection
Microchimica Acta · 2025
DOI: 10.1007/s00604-025-07043-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Dajiang Kuang und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Textile Science and Engineering, Jiangnan University, 1800 Lihu Road, Wuxi, 214122, China. Hauptthemen laut MEDLINE: Sweat, Fibroins, Nanotubes, Carbon, Biosensing Techniques. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Incorporating silk fibroin (SF) into the biosensing platform provides a level of flexibility and macro-structure control that holds immense importance for monitoring of sweat pH. It accomplishes non-invasive surveillance of the human physiology while concurrently tackling the issue of electrode-skin friction. The preparation of the multi-walled carbon nanotubes (MWCNTs)/polyaniline (PANI) silk fibroin pH-responsive microneedle array sensor involves the dispersion of PANI powder in silk fibroin and the addition of MWCNTs for the analysis of human sweat. The template method offers an efficient and straightforward means of producing microneedles with a high degree of precision, achieving micrometer resolution. The pH sensor is designed with a two-electrode configuration, comprising an MWCNTs/PANI silk fibroin microneedle array sensing electrode as well as an Ag/AgCl reference electrode. The pH sensor shows a sensitivity of 53.60 mV/pH over the pH range 3 to 9, a response time of 68 s, and a recovery time of 77 s. The pH sensor displays other outstanding sensor performances regarding reversibility, repeatability, selectivity, and stability. The pH sensor is capable of detecting alterations in the pH levels of human sweat.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Textile Science and Engineering, Jiangnan University, 1800 Lihu Road, Wuxi, 214122, China.
- College of Textile Science and Engineering, Jiangnan University, 1800 Lihu Road, Wuxi, 214122, China. wangchaoxia@sohu.com.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Kuang, D., Tan, Y., Song, L., Tang, J., & Wang, C. (2025). MWCNTs/PANI silk fibroin film sensor based on microneedle array for sweat pH detection. Microchimica Acta. https://doi.org/10.1007/s00604-025-07043-x
Vancouver
Kuang D, Tan Y, Song L, Tang J, Wang C. MWCNTs/PANI silk fibroin film sensor based on microneedle array for sweat pH detection. Microchimica Acta. 2025. doi:10.1007/s00604-025-07043-x
BibTeX
@article{Kuang2025,
author = {Kuang, Dajiang and Tan, Yongsong and Song, Liyang and Tang, Jinglei and Wang, Chaoxia},
title = {MWCNTs/PANI silk fibroin film sensor based on microneedle array for sweat pH detection},
journal = {Microchimica Acta},
year = {2025},
doi = {10.1007/s00604-025-07043-x}
}
EUVIMED