EUVIMEDEUVIMED entdecken
Crossref

An integrated immunofluorescent detection system for automated and sensitive protein quantification based on a microfluidic flow cytometry platform

Lin Cheng, Yitong Li, Weiwei Ji, Jing Yan

Analytica Chimica Acta · 2025-03 · 1341 · 343658

DOI: 10.1016/j.aca.2025.343658 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-03. Verfasst von Lin Cheng und 3 weiteren Autor:innen. Beteiligte Einrichtung: Holosensor Medical Technology Ltd, Room 12, No. 1798, Zhonghuayuan West Road, Yushan Town, Suzhou, 215000, China. Hauptthemen laut MEDLINE: Flow Cytometry, Interleukin-6, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid and sensitive protein detection methods are of benefit to clinical diagnosis, pathological mechanism research, and infection prevention. However, routine protein detection technologies, such as enzyme-linked immunosorbent assay and Western blot, suffer from low sensitivity, poor quantification and labourious operation. Herein, we developed a fully automated protein analysis system to conduct fast protein quantification at the single molecular level. It streamlines antibody-coated beads-based protein capture, fluorescent labelling with fluorophore-conjugated antibodies, and flow-cytometric optical detection in a microfluidic chip, achieving sample-in quantitative result-out protein detection within 60 min. This platform employs a combination of spiral and ultrasonic mixing, and realizes highly efficient protein capture and immunolabelling. Leveraging non-Newtonian fluids, the beads can be well-aligned at the focus of the optical module, yielding robust protein quantification results with a low coefficient of variation of 0.4 %. As a proof of concept, interleukin 6 was determined using the integrated instrument. The results showed good linear correlation (R2 = 0.9938) with that obtained from Roche Electrochemiluminescence Immunoassay Analyzer (ECLIA). Moreover, the single molecule immunoanalyzer achieved a lower limit of detection (LOD) of 16 fg/mL and exhibited an 8-fold increase in sensitivity compared to ECLIA. With short turnaround time and less human intervention, the developed protein quantification system could become a valuable tool for detection of disease markers and precision medicine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flow CytometryInterleukin-6Microfluidic Analytical TechniquesLab-On-A-Chip DevicesFluorescent Antibody TechniqueHumansLimit of DetectionAutomation

Stichwörter der Autor:innen

Flow cytometryMicrofluidicNon-Newtonian fluidSingle-molecule immunoassay equipmentSpiral mixingUltrasonic mixer

Substanzen

Interleukin-6

Autor:innen und Institutionen

  • Holosensor Medical Technology Ltd, Room 12, No. 1798, Zhonghuayuan West Road, Yushan Town, Suzhou, 215000, China.
  • Holosensor Medical Technology Ltd, Room 12, No. 1798, Zhonghuayuan West Road, Yushan Town, Suzhou, 215000, China; Department of Veterinary Medicine, University of Cambridge, Cambridge, UK. Electronic address: yanjing@ho…

Zitieren

APA

Cheng, L., Li, Y., Ji, W., & Yan, J. (2025). An integrated immunofluorescent detection system for automated and sensitive protein quantification based on a microfluidic flow cytometry platform. Analytica Chimica Acta, 1341, 343658. https://doi.org/10.1016/j.aca.2025.343658

Vancouver

Cheng L, Li Y, Ji W, Yan J. An integrated immunofluorescent detection system for automated and sensitive protein quantification based on a microfluidic flow cytometry platform. Analytica Chimica Acta. 2025;1341:343658. doi:10.1016/j.aca.2025.343658

BibTeX
@article{Cheng2025,
  author = {Cheng, Lin and Li, Yitong and Ji, Weiwei and Yan, Jing},
  title = {An integrated immunofluorescent detection system for automated and sensitive protein quantification based on a microfluidic flow cytometry platform},
  journal = {Analytica Chimica Acta},
  year = {2025},
  volume = {1341},
  pages = {343658},
  doi = {10.1016/j.aca.2025.343658}
}
Kostenlos starten →