A dual-mode aptasensor based on rolling circle amplification enriched G-quadruplex for highly sensitive IFN-γ detection
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2024.343254 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Lianhui Zhao und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Life Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China. Hauptthemen laut MEDLINE: G-Quadruplexes, Aptamers, Nucleotide, Interferon-gamma, Nucleic Acid Amplification Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: China-Japan Friendship Hospital, Beijing University of Chemical Technology, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
BACKGROUND: Aptasensors have been extensively utilized in target detection due to their advantages of high sensitivity and fast response. However, the reliability of the detection results of the single-mode aptasensor cannot be verified in time. Developing efficient detection methods with cross-validation capability is beneficial to achieving highly reliable detection. This study aims to design a colorimetric and fluorescent dual-mode aptasensor by skillfully engineering G-quadruplex assembly and rolling circle amplification for highly reliable IFN-γ detection. RESULTS: The complexes of anti-IFN-γ aptamers and complement sequences (cDNA) were modified on the magnetic beads. In the presence of IFN-γ, the preferential combination of aptamers with IFN-γ resulted in the release of cDNAs. The cDNAs were collected by magnetic separation and then used as primers to trigger rolling circle amplification reaction to generate enriched G-quadruplexes. The G-quadruplex could be utilized to combine with hemin to catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine for colormetric mode or to couple with the fluorogenic dye Thioflavin T for fluorescent mode. The developed dual-mode aptasensor displayed a linear range of 1-10000 pM with a detection limit of 0.406 pM for the colormetric mode and a range of 0.1-10000 pM with a detection limit of 0.037 pM for the fluorescent mode. Further, the designed aptasensor was applied to IFN-γ detection in serum samples and achieved satisfactory recoveries. SIGNIFICANCE: This innovative dual-mode detection strategy skillfully leverages the effective target-binding ability of aptamer, dual-function of the G-quadruplex and the signal amplifying ability of rolling circle amplification. This approach not only provides a reliable testing tool for the detection of IFN-γ, but also promotes the development of multimode sensing platforms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Life Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China.
- Department of Microbiology and Immunology, College of Medicine, Drexel University, Philadelphia, 19102, USA.
- College of Food Science and Engineering, Ocean University of China, Qingdao, 266404, China.
- College of Life Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China. Electronic address: yydong@mail.buct.edu.cn.
Förderung
- China-Japan Friendship Hospital
- Beijing University of Chemical Technology
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Zhao, L., Yin, Y., Xiao, S., Qiu, Y., Wang, S., & Dong, Y. (2024). A dual-mode aptasensor based on rolling circle amplification enriched G-quadruplex for highly sensitive IFN-γ detection. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.343254
Vancouver
Zhao L, Yin Y, Xiao S, Qiu Y, Wang S, Dong Y. A dual-mode aptasensor based on rolling circle amplification enriched G-quadruplex for highly sensitive IFN-γ detection. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.343254
BibTeX
@article{Zhao2024,
author = {Zhao, Lianhui and Yin, Yingai and Xiao, Shuqi and Qiu, Yinghua and Wang, Sai and Dong, Yiyang},
title = {A dual-mode aptasensor based on rolling circle amplification enriched G-quadruplex for highly sensitive IFN-γ detection},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2024.343254}
}
EUVIMED