Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Qianjie Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI, 48824, USA; Department of Biochemistry and Molecular Biology, …. Hauptthemen laut MEDLINE: Electrophoresis, Capillary, Proteomics, Electroosmosis, Cations. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIGMS NIH HHS, National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) has become a valuable analytical technique in top-down proteomics (TDP). CZE-MS/MS-based TDP typically employs separation capillaries with neutral coatings (i.e., linear polyacrylamide, LPA). However, issues related to separation resolution and reproducibility remain with the LPA-coated capillaries due to the unavoidable non-specific protein adsorption onto the capillary wall. Cationic coatings can be critical alternatives to LPA coating for CZE-MS/MS-based TDP due to the electrostatic repulsion between the positively charged capillary inner wall and proteoform molecules in the acidic separation buffer. Unfortunately, there are only very few studies using cationic coating-based CZE-MS/MS for TDP studies. RESULTS: In this work, we aimed to develop a simple and efficient approach for preparing separation capillaries with a cationic coating, i.e., poly (acrylamide-co-(3-acrylamidopropyl) trimethylammonium chloride [PAMAPTAC]) for CZE-MS/MS-based TDP. The PAMAPTAC coating-based CZE-MS produced significantly better separation resolution of proteoforms compared to the traditionally used LPA-coated approach. It achieved reproducible separation and measurement of a simple proteoform mixture and a complex proteome sample (i.e., a yeast cell lysate) regarding migration time, proteoform intensity, and the number of proteoform identifications. The PAMAPTAC coating-based CZE-MS enabled the detection of large proteoforms (≥30 kDa) from the yeast cell lysate reproducibly without any size-based prefractionation. Interestingly, the mobility of proteoforms using the PAMAPTAC coating can be predicted accurately using a simple semi-empirical model. SIGNIFICANCE: The results render the PAMAPTAC coating as a valuable alternative to the LPA coating to advance CZE-MS-based TDP towards high-resolution separation and highly reproducible measurement of proteoforms in complex samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrophoresis, CapillaryProteomicsElectroosmosisCationsTandem Mass SpectrometrySaccharomyces cerevisiae

Stichwörter der Autor:innen

Capillary zone electrophoresis-mass spectrometryCovalent cationic coatingLarge proteoformsProteoformReproducibilityTop-down proteomics

Substanzen

Cations

Autor:innen und Institutionen

  • Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI, 48824, USA; Department of Biochemistry and Molecular Biology, Michigan State University, East Lansing, MI, 48824, USA; Plant Resilie…
  • Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI, 48824, USA.
  • Department of Biochemistry and Molecular Biology, Michigan State University, East Lansing, MI, 48824, USA; Plant Resilience Institute, Michigan State University, East Lansing, MI, 48824, USA.
  • Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI, 48824, USA. Electronic address: lsun@chemistry.msu.edu.

Förderung

  • NCI NIH HHS
  • NIGMS NIH HHS
  • National Science Foundation
  • National Institute of General Medical Sciences
  • National Cancer Institute

Zitieren

APA

Wang, Q., Gao, G., Fang, F., Wang, Q., Lundquist, P. K., & Sun, L. (2024). A simple and efficient approach for preparing cationic coating with tunable electroosmotic flow for capillary zone electrophoresis-mass spectrometry-based top-down proteomics. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.343162

Vancouver

Wang Q, Gao G, Fang F, Wang Q, Lundquist PK, Sun L. A simple and efficient approach for preparing cationic coating with tunable electroosmotic flow for capillary zone electrophoresis-mass spectrometry-based top-down proteomics. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.343162

BibTeX
@article{Wang2024,
  author = {Wang, Qianjie and Gao, Guangyao and Fang, Fei and Wang, Qianyi and Lundquist, Peter K and Sun, Liangliang},
  title = {A simple and efficient approach for preparing cationic coating with tunable electroosmotic flow for capillary zone electrophoresis-mass spectrometry-based top-down proteomics},
  journal = {Analytica Chimica Acta},
  year = {2024},
  doi = {10.1016/j.aca.2024.343162}
}
Kostenlos starten →