Reproducible Capillary Electrophoresis–Mass Spectrometry–Based Top‐Down Proteomics of Complex Proteomes Enabled by an Advanced Cationic Polymer Coating
Journal of Mass Spectrometry · 2026
DOI: 10.1002/jms.70005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Mass Spectrometry, 2026. Verfasst von Guangyao Gao und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Michigan State University, East Lansing, Michigan, USA. Hauptthemen laut MEDLINE: Proteomics, Mass Spectrometry, Proteome, Polymers. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIGMS NIH HHS, National Science Foundation, NCI NIH HHS.
Abstract (Originalsprache)
Capillary zone electrophoresis–mass spectrometry (CZE‐MS) has become a powerful tool for top‐down proteomics (TDP). Capillaries are commonly coated with neutral or cationic polymers to reduce protein adsorption in CZE‐MS. We recently introduced a cationic polymer coating [poly(acrylamide‐co‐(3‐acrylamidopropyl) trimethylammonium chloride (PAMAPTAC)] to CZE‐MS–based TDP. Here, we further improved the coating procedure to enhance the ease and repeatability of the cationic coating preparation by employing 2,2′‐azobisisobutyronitrile (AIBN) as the radical initiator and methanol as the solvent. The new coating method not only simplifies the coating process but is also user‐friendly. Different laboratory members were able to reproduce this type of cationic coating with consistent CZE‐MS performance. We evaluated the performance of CZE‐MS with the cationic coating in analyzing various complex biological samples (nanoparticle protein corona, histone, and an Escherichia coli cell lysate) and assessed its long‐term reproducibility with an E. coli cell lysate for 35 runs (over 40 h) of continuous measurement. The CZE‐MS system produced reproducible measurements for all the samples regarding separation profiles, proteoform migration time (MT), and proteoform intensity. For example, the system enabled the detection of large proteoforms (26–35 kDa) from an E. coli sample with consistent MT, relative standard deviations (RSDs)
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Michigan State University, East Lansing, Michigan, USA.
ORCID-Profile: Liangliang Sun
Förderung
- NIGMS NIH HHS
- National Science Foundation
- NCI NIH HHS
- National Institute of General Medical Sciences
Zitieren
APA
Gao, G., Fang, F., Yue, Y., Zhang, A. T., Wang, Q., Wang, Q., Zhu, G., & Sun, L. (2026). Reproducible Capillary Electrophoresis–Mass Spectrometry–Based Top‐Down Proteomics of Complex Proteomes Enabled by an Advanced Cationic Polymer Coating. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.70005
Vancouver
Gao G, Fang F, Yue Y, Zhang AT, Wang Q, Wang Q, et al. Reproducible Capillary Electrophoresis–Mass Spectrometry–Based Top‐Down Proteomics of Complex Proteomes Enabled by an Advanced Cationic Polymer Coating. Journal of Mass Spectrometry. 2026. doi:10.1002/jms.70005
BibTeX
@article{Gao2026,
author = {Gao, Guangyao and Fang, Fei and Yue, Yifan and Zhang, Alex T and Wang, Qianjie and Wang, Qianyi and Zhu, Guijie and Sun, Liangliang},
title = {Reproducible Capillary Electrophoresis–Mass Spectrometry–Based Top‐Down Proteomics of Complex Proteomes Enabled by an Advanced Cationic Polymer Coating},
journal = {Journal of Mass Spectrometry},
year = {2026},
doi = {10.1002/jms.70005}
}
EUVIMED