EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Facilitating inorganic arsenic speciation and quantification in waters: Polymer inclusion membrane preconcentration and X-ray fluorescence detection

Donatella Chillè, Eva Marguí, Enriqueta Anticó, Claudia Foti, Clàudia Fontàs

Analytica Chimica Acta · 2024-10 · 1324 · 343098

DOI: 10.1016/j.aca.2024.343098 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-10. Verfasst von Donatella Chillè und 4 weiteren Autor:innen. Beteiligte Einrichtung: Chemistry Department, University of Girona, C/ Maria Aurèlia Capmany, 69, 17003, Girona, Spain; Department of Chemical, Biological, Pharmaceutical an…. Hauptthemen laut MEDLINE: Water Pollutants, Chemical, Polymers, Arsenic, Spectrometry, X-Ray Emission. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: European Regional Development Fund, European Commission, Gobierno de España Ministerio de Ciencia, Innovación y Universidades.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Arsenic, classified as a priority pollutant and human carcinogen by the IARC, is subject to stringent regulatory limits in food and water. Among various arsenic species found in water samples, arsenite (As(III)) is identified as the most toxic form. Given the limitations of conventional spectroscopic techniques in speciation analysis, there is a crucial need for innovative and sustainable methodologies that enable arsenic speciation. Simplifying these methodologies is essential for widespread applicability and effective environmental monitoring. RESULTS: This study proposes a simple and cost-effective analytical methodology for speciating inorganic arsenic in water samples. The method involves extracting As(III) into a polymer inclusion membrane (PIM) containing the extractant Cyanex 301 (bis(2,4,4-trimethylpentyl) dithiophosphinic acid), followed by analysis using energy dispersive X-ray fluorescence (EDXRF) spectrometry. The concentration of arsenate was measured after a reduction step using a thiosulfate/iodide mixture. This simple methodology allows a limit of quantification for trivalent arsenic (2 μg L-1), which is well below the World Health Organization's recommended maximum permissible level of As in drinking water (10 μg L-1). The method that is developed allows the determination of As at trace levels in waters with naturally occurring arsenic. SIGNIFICANCE AND NOVELTY: This study represents a significant advance in the field, providing a novel and efficient methodology for arsenic speciation analysis in water samples. By combining the advantages of polymer inclusion membrane (PIM) extraction with energy dispersive X-ray fluorescence (EDXRF) spectrometry, this study offers a cost-effective and environmentally friendly approach to address the critical issue of arsenic contamination in water sources, thereby contributing to enhanced environmental monitoring and public health protection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Water Pollutants, ChemicalPolymersArsenicSpectrometry, X-Ray EmissionMembranes, Artificial

Stichwörter der Autor:innen

ArsenicCyanex 301Polymer inclusion membraneSpeciationX-ray fluorescence spectrometry

Substanzen

Water Pollutants, ChemicalPolymersArsenicMembranes, Artificial

Autor:innen und Institutionen

  • Chemistry Department, University of Girona, C/ Maria Aurèlia Capmany, 69, 17003, Girona, Spain; Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Viale Ferdinando Stag…
  • Chemistry Department, University of Girona, C/ Maria Aurèlia Capmany, 69, 17003, Girona, Spain.
  • Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Viale Ferdinando Stagno d'Alcontres 31, 98166, Messina, Italy.
  • Chemistry Department, University of Girona, C/ Maria Aurèlia Capmany, 69, 17003, Girona, Spain. Electronic address: claudia.fontas@udg.edu.

Förderung

  • European Regional Development Fund
  • European Commission
  • Gobierno de España Ministerio de Ciencia, Innovación y Universidades

Zitieren

APA

Chillè, D., Marguí, E., Anticó, E., Foti, C., & Fontàs, C. (2024). Facilitating inorganic arsenic speciation and quantification in waters: Polymer inclusion membrane preconcentration and X-ray fluorescence detection. Analytica Chimica Acta, 1324, 343098. https://doi.org/10.1016/j.aca.2024.343098

Vancouver

Chillè D, Marguí E, Anticó E, Foti C, Fontàs C. Facilitating inorganic arsenic speciation and quantification in waters: Polymer inclusion membrane preconcentration and X-ray fluorescence detection. Analytica Chimica Acta. 2024;1324:343098. doi:10.1016/j.aca.2024.343098

BibTeX
@article{Chill2024,
  author = {Chillè, Donatella and Marguí, Eva and Anticó, Enriqueta and Foti, Claudia and Fontàs, Clàudia},
  title = {Facilitating inorganic arsenic speciation and quantification in waters: Polymer inclusion membrane preconcentration and X-ray fluorescence detection},
  journal = {Analytica Chimica Acta},
  year = {2024},
  volume = {1324},
  pages = {343098},
  doi = {10.1016/j.aca.2024.343098}
}
Kostenlos starten →