An antifouling electrochemical biosensor based on oxidized bacterial cellulose and quaternized chitosan for reliable detection of involucrin in wound exudate
Analytica Chimica Acta · 2024-08 · 1316 · 342821
DOI: 10.1016/j.aca.2024.342821 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-08. Verfasst von Mingrui Lv und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of …. Hauptthemen laut MEDLINE: Biosensing Techniques, Chitosan, Cellulose, Electrochemical Techniques. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Technology Research and Development Program of Shandong Province.
Abstract (Originalsprache)
The monitoring of biomarkers in wound exudate is of great importance for wound care and treatment, and electrochemical biosensors with high sensitivity are potentially useful for this purpose. However, conventional electrochemical biosensors always suffer from severe biofouling when performed in the complex wound exudate. Herein, an antifouling electrochemical biosensor for the detection of involucrin in wound exudate was developed based on a wound dressing, oxidized bacterial cellulose (OxBC) and quaternized chitosan (QCS) composite hydrogel. The OxBC/QCS hydrogel was prepared using an in-situ chemical oxidation and physical blending method, and the proportion of OxBC and QCS was optimized to achieve electrical neutrality and enhanced hydrophilicity, therefore endowing the hydrogel with exceptional antifouling and antimicrobial properties. The involucrin antibody SY5 was covalently bound to the OxBC/QCS hydrogel to construct the biosensor, and it demonstrated a low limit of detection down to 0.45 pg mL-1 and a linear detection range from 1.0 pg mL-1 to 1.0 μg mL-1, and it was capable of detecting targets in wound exudate. Crucially, the unique antifouling and antimicrobial capability of the OxBC/QCS hydrogel not only extends its effective lifespan but also guarantees the sensing performance of the biosensor. The successful application of this wound dressing, OxBC/QCS hydrogel for involucrin detection in wound exudate demonstrates its promising potential in wound healing monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science & T…
Förderung
- National Natural Science Foundation of China
- Key Technology Research and Development Program of Shandong Province
Zitieren
APA
Lv, M., Li, Y., Qiao, X., Zeng, X., & Luo, X. (2024). An antifouling electrochemical biosensor based on oxidized bacterial cellulose and quaternized chitosan for reliable detection of involucrin in wound exudate. Analytica Chimica Acta, 1316, 342821. https://doi.org/10.1016/j.aca.2024.342821
Vancouver
Lv M, Li Y, Qiao X, Zeng X, Luo X. An antifouling electrochemical biosensor based on oxidized bacterial cellulose and quaternized chitosan for reliable detection of involucrin in wound exudate. Analytica Chimica Acta. 2024;1316:342821. doi:10.1016/j.aca.2024.342821
BibTeX
@article{Lv2024,
author = {Lv, Mingrui and Li, Yanxin and Qiao, Xiujuan and Zeng, Xianghua and Luo, Xiliang},
title = {An antifouling electrochemical biosensor based on oxidized bacterial cellulose and quaternized chitosan for reliable detection of involucrin in wound exudate},
journal = {Analytica Chimica Acta},
year = {2024},
volume = {1316},
pages = {342821},
doi = {10.1016/j.aca.2024.342821}
}
EUVIMED