EUVIMEDEUVIMED entdecken
Crossref

Peptide-integrated bovine serum albumin hydrogel as a synergistic antifouling strategy for electrochemical detection of cardiac troponin I in serum

Qiushu Du, Peipei Wang, Zhen Song, Xiliang Luo, Shaoping Lv

Analytica Chimica Acta · 2026

DOI: 10.1016/j.aca.2026.346092 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Qiushu Du und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China; State Key Laboratory of Adva…. Hauptthemen laut MEDLINE: Troponin I, Serum Albumin, Bovine, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Shandong Province Natural Science Foundation, Natural Science Foundation of Qingdao, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemical biosensors often suffer from biofouling in complex biological samples, which compromises detection accuracy and limits their practical applicability. To address this problem, we developed a synergistic antifouling biosensor by integrating the bovine serum albumin hydrogel (BSAG) with a designed multifunctional peptide for the detection of cardiac troponin I (cTnI) in complex biofluids. A stable and versatile antifouling layer was constructed via a facile one-step crosslinking method based on bovine serum albumin (BSA), and the amino-enriched surface of BSA enabled the secondary grafting of a multifunctional peptide that combines with anchoring, antifouling, and recognition properties. This approach not only enhanced the antifouling performance and durability of the coating, but also avoided potential interference associated with the introduction of exogenous recognition molecules. The cooperative antifouling performance of this hierarchical interface was systematically validated through electrochemical measurements and fluorescence imaging, demonstrating excellent resistance to biofouling in various biological fluids. The fabricated biosensor possessed long-term stability, high sensitivity and a broad linear response was obtained within the range of 0.1 pg mL-1 - 100 ng mL-1, accompanied by a low detection limit of 0.042 pg mL-1. Overall, this study presents a robust and generalizable interface engineering strategy that significantly enhances biosensor antifouling performance and analytical reliability, highlighting its strong potential for clinical monitoring in complex biological environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin ISerum Albumin, BovineElectrochemical TechniquesBiosensing TechniquesPeptidesBiofoulingHydrogelsAnimalsCattleHumansLimit of Detection

Stichwörter der Autor:innen

AntifoulingBovine serum albumin hydrogelCardiac troponin IElectrochemical biosensorPeptide

Substanzen

Troponin ISerum Albumin, BovinePeptidesHydrogels

Autor:innen und Institutionen

  • College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China; State Key Laboratory of Advanced Optical Polymer and Manufacturing Technology, Qingdao, 266042, PR…
  • Department of Rehabilitation Medicine, Qingdao Central Hospital, University of Health and Rehabilitation Sciences, Qingdao, 266000, PR China.
  • Department of Rehabilitation Medicine, Qingdao Central Hospital, University of Health and Rehabilitation Sciences, Qingdao, 266000, PR China. Electronic address: lvshaoping170702@163.com.

Förderung

  • Shandong Province Natural Science Foundation
  • Natural Science Foundation of Qingdao
  • National Natural Science Foundation of China

Zitieren

APA

Du, Q., Wang, P., Song, Z., Luo, X., & Lv, S. (2026). Peptide-integrated bovine serum albumin hydrogel as a synergistic antifouling strategy for electrochemical detection of cardiac troponin I in serum. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.346092

Vancouver

Du Q, Wang P, Song Z, Luo X, Lv S. Peptide-integrated bovine serum albumin hydrogel as a synergistic antifouling strategy for electrochemical detection of cardiac troponin I in serum. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.346092

BibTeX
@article{Du2026,
  author = {Du, Qiushu and Wang, Peipei and Song, Zhen and Luo, Xiliang and Lv, Shaoping},
  title = {Peptide-integrated bovine serum albumin hydrogel as a synergistic antifouling strategy for electrochemical detection of cardiac troponin I in serum},
  journal = {Analytica Chimica Acta},
  year = {2026},
  doi = {10.1016/j.aca.2026.346092}
}
Kostenlos starten →