CdS/Bi2S3/NiS ternary heterostructure-based photoelectrochemical immunosensor for the sensitive detection of carbohydrate antigen 125
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2024.342765 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Shulei Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, Hubei Province, 430072, PR China. Hauptthemen laut MEDLINE: Cadmium Compounds, Sulfides, Electrochemical Techniques, CA-125 Antigen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
The sensitive, accurate and rapid detection of carbohydrate antigen 125 (CA125) is essential for the early diagnosis and clinical management of ovarian cancer, but there is still challenge. Herein, a photoelectrochemical (PEC) immunosensor based on CdS/Bi2S3/NiS ternary sulfide heterostructured photocatalyst was presented for the detection of CA125. The CdS/Bi2S3/NiS was synthesized by a one-step hydrothermal approach. The heterojunction comprising of CdS and Bi2S3 could separate photogenerated carriers, the introduced narrow bandgap NiS could act as electron-conducting bridge to facilitate the transfer of interfacial photogenerated electrons, thereby improving the photoelectric conversion efficiency. Due to their synergistic effect, the photocurrent response produced by the composite was up to 14.6 times of pure CdS. On the basis, a PEC immunosensor was constructed by introducing the CA125 antibody through thioglycolic acid linkage. It was found that the resulting immunosensor showed good performance. Under the optimized conditions, its linear detection range was as wide as 1 pg mL-1-50 ng mL-1, and the detection limit was low to 0.85 pg mL-1. Furthermore, we experimentally tested its anti-interference, stability and reproducibility, and satisfactory results were achieved. The practicable feasibility of the sensor was confirmed by testing serum sample. Thus this work provided a simple, fast and enough sensitive approach for CA125 monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, Hubei Province, 430072, PR China.
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, Hubei Province, 430072, PR China. Electronic address: fqzhao@whu.edu.cn.
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, Hubei Province, 430072, PR China. Electronic address: bzzeng@whu.edu.cn.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Wang, S., Yuan, J., Wang, C., Wang, T., Zhao, F., & Zeng, B. (2024). CdS/Bi2S3/NiS ternary heterostructure-based photoelectrochemical immunosensor for the sensitive detection of carbohydrate antigen 125. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342765
Vancouver
Wang S, Yuan J, Wang C, Wang T, Zhao F, Zeng B. CdS/Bi2S3/NiS ternary heterostructure-based photoelectrochemical immunosensor for the sensitive detection of carbohydrate antigen 125. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342765
BibTeX
@article{Wang2024,
author = {Wang, Shulei and Yuan, Jingxia and Wang, Chunfang and Wang, Tingting and Zhao, Faqiong and Zeng, Baizhao},
title = {CdS/Bi2S3/NiS ternary heterostructure-based photoelectrochemical immunosensor for the sensitive detection of carbohydrate antigen 125},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2024.342765}
}
EUVIMED