Freestanding plasmonic BiVO4@AuNPs//dendritic CdS QDs with programmable carrier-direction switching for low-background photoelectrochemical PARP-1 detection in cancer tissues
Biosensors and Bioelectronics · 2026
DOI: 10.1016/j.bios.2025.118333 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Xiuhua Yuan und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical and Automotive Engineering, Liaocheng University, Liaocheng, China. Hauptthemen laut MEDLINE: Quantum Dots, Biosensing Techniques, Poly (ADP-Ribose) Polymerase-1, Bismuth. Die Arbeit nennt 37 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Chinese Academy of Sciences, Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
Precise manipulation of interfacial charge carrier transport is essential for developing high-performance photoelectrochemical (PEC) biosensors with minimal background and high anti-interference capability in complex matrices. In this work, we present a novel low-background PEC biosensing platform capable of programmable switching of carrier transfer direction for the sensitive detection of PARP-1 in cancer tissues. The sensing architecture is based on freestanding plasmonic Schottky junctions formed by integrating Au nanoparticles into electrospun BiVO4 nanofibers. These junctions not only invert the inherent carrier transport direction but also suppress the background photocurrent to nearly zero through localized surface plasmon resonance effects. Upon target recognition, PARP-1 binds to thiol-modified double-stranded DNA (SH-dsDNA) and catalyzes the transfer of biotinylated ADP-ribose from NAD+, yielding SH-dsDNA-PARP-1 copolymers. Subsequent introduction of streptavidin-conjugated single-stranded DNA triggers hyperbranched rolling circle amplification, generating elongated DNA templates that selectively capture complementary DNA-functionalized CdS quantum dots (QDs). Capitalizing on the intrinsic sulfhydryl groups of the copolymer, high-density CdS QDs are assembled via multivalent Au-S bonds, forming a dual-template structure comprising the PARP-polymer conjugate and a dendritic DNA scaffold. This design enables programmable QD organization, facilitating one-to-many cascaded signal amplification and programmable switching of carrier transfer direction. By combining the near-zero background of BiVO4@AuNPs with the dramatically enhanced cathodic photocurrent from the densely grafted CdS QDs, the constructed "On-Off-super On" biosensor achieves an exceptional detection limit of 4.48 × 10-7 U·μL-1 for PARP-1 over a broad linear range in lung cancer tissue. This study offers a universal strategy to be used for clinical diagnosis and PARP-1 inhibitor research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Mechanical and Automotive Engineering, Liaocheng University, Liaocheng, China.
- School of Chemistry and Chemical Engineering, Liaocheng University, China.
- School of Mechanical and Automotive Engineering, Liaocheng University, Liaocheng, China. Electronic address: sunqun@lcu.edu.cn.
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, China.
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, Shandong, China.
- School of Chemistry and Chemical Engineering, Liaocheng University, China. Electronic address: xueqingwang1983@163.com.
Förderung
- National Natural Science Foundation of China
- Chinese Academy of Sciences
- Natural Science Foundation of Shandong Province
Zitieren
APA
Yuan, X., Li, Y., Zhang, F., Xie, J., Sun, Q., Zhou, L., Lv, Y., Xue, Q., Li, C. Z., & Li, X. (2026). Freestanding plasmonic BiVO4@AuNPs//dendritic CdS QDs with programmable carrier-direction switching for low-background photoelectrochemical PARP-1 detection in cancer tissues. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.118333
Vancouver
Yuan X, Li Y, Zhang F, Xie J, Sun Q, Zhou L, et al. Freestanding plasmonic BiVO4@AuNPs//dendritic CdS QDs with programmable carrier-direction switching for low-background photoelectrochemical PARP-1 detection in cancer tissues. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2025.118333
BibTeX
@article{Yuan2026,
author = {Yuan, Xiuhua and Li, Yanli and Zhang, Fengqi and Xie, Jiajing and Sun, Qun and Zhou, Lianqun and Lv, Yanqin and Xue, Qingwang and Li, Chen-Zhong and Li, Xia},
title = {Freestanding plasmonic BiVO4@AuNPs//dendritic CdS QDs with programmable carrier-direction switching for low-background photoelectrochemical PARP-1 detection in cancer tissues},
journal = {Biosensors and Bioelectronics},
year = {2026},
doi = {10.1016/j.bios.2025.118333}
}
EUVIMED