EUVIMEDEUVIMED entdecken
Crossref

Sensitive electrochemical biosensor for rapid detection of sEV-miRNA based turbo-like localized catalytic hairpin assembly

Huiqin Zhu, Siting Chen, Fei Lan, Wenbin Li, Tingting Ji, Lifeng Zhang, Yuhang Guo, Weilun Pan, Shihua Luo, Rongzhang Xie

Analytica Chimica Acta · 2024-07 · 1311 · 342704

DOI: 10.1016/j.aca.2024.342704 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-07. Verfasst von Huiqin Zhu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, YunFu People's Hospital, Yunfu, Guangdong, 527300, PR China; YunFu Key Laboratory of Brain Diseases Research, YunF…. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques, MicroRNAs, Gold. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Guangdong Medical Research Foundation, National Natural Science Foundation of China, China Postdoctoral Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Small extracellular vesicle-associated microRNAs (sEV-miRNAs) have emerged as critical biomarkers for cancer diagnosis, yet the rapid detection of these low-abundance molecules in clinical samples remains a formidable challenge. Herein, a simple turbo-like localized catalytic hairpin assembly (TL-CHA) was proposed for sEV-miR-1246 measurement. This electrochemical sensor achieves dual localization through the ingeniously use of AuNPs and DNA nanowires, which provides rich sites for CHA cascade amplification, significantly enhancing the effective reaction and amplify the detection response. Leveraging this innovative design, this biosensor demonstrated the ability to detect sEV-miRNA at concentrations as low as 5.24 aM in a time frame of 30 min. The precision of the measurements was validated through reverse transcription quantitative polymerase chain reaction. Furthermore, the sensor was used for analyzing plasma samples from gastric cancer patients yielded AUC values of 0.973 for all stages and 0.945 for early stages. This demonstrates the sensor's robust performance in both the staging diagnosis and early screening of gastric cancer. Therefore, this platform has great potential for the clinical cancer diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesElectrochemical TechniquesMicroRNAsGoldHumansMetal NanoparticlesStomach NeoplasmsLimit of DetectionCatalysisNanowires

Stichwörter der Autor:innen

Cancer diagnosticsCatalyzed hairpin assemblyDNA nanowireGold nanoparticlesEV-miRNA

Substanzen

MicroRNAsGold

Autor:innen und Institutionen

  • Department of Clinical Laboratory, YunFu People's Hospital, Yunfu, Guangdong, 527300, PR China; YunFu Key Laboratory of Brain Diseases Research, YunFu People's Hospital, Yunfu, 527300, PR China.
  • Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, PR China; Pathology Department, Affiliated Qingyuan Hospital of Guangzhou Medical University, Qingyuan People's Hospit…
  • Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, PR China.
  • Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, PR China. Electronic address: nfyypanwl@163.com.
  • Center for Clinical Laboratory Diagnosis and Research, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, 533000, Guangxi, PR China; Key Laboratory of Research on Clinical Molecular Diagnosis f…
  • Department of Clinical Laboratory, YunFu People's Hospital, Yunfu, Guangdong, 527300, PR China; YunFu Key Laboratory of Brain Diseases Research, YunFu People's Hospital, Yunfu, 527300, PR China. Electronic address: xier…

Förderung

  • Guangdong Medical Research Foundation
  • National Natural Science Foundation of China
  • China Postdoctoral Science Foundation

Zitieren

APA

Zhu, H., Chen, S., Lan, F., Li, W., Ji, T., Zhang, L., Guo, Y., Pan, W., Luo, S., & Xie, R. (2024). Sensitive electrochemical biosensor for rapid detection of sEV-miRNA based turbo-like localized catalytic hairpin assembly. Analytica Chimica Acta, 1311, 342704. https://doi.org/10.1016/j.aca.2024.342704

Vancouver

Zhu H, Chen S, Lan F, Li W, Ji T, Zhang L, et al. Sensitive electrochemical biosensor for rapid detection of sEV-miRNA based turbo-like localized catalytic hairpin assembly. Analytica Chimica Acta. 2024;1311:342704. doi:10.1016/j.aca.2024.342704

BibTeX
@article{Zhu2024,
  author = {Zhu, Huiqin and Chen, Siting and Lan, Fei and Li, Wenbin and Ji, Tingting and Zhang, Lifeng and Guo, Yuhang and Pan, Weilun and Luo, Shihua and Xie, Rongzhang},
  title = {Sensitive electrochemical biosensor for rapid detection of sEV-miRNA based turbo-like localized catalytic hairpin assembly},
  journal = {Analytica Chimica Acta},
  year = {2024},
  volume = {1311},
  pages = {342704},
  doi = {10.1016/j.aca.2024.342704}
}
Kostenlos starten →