A dry chemistry-based self-enhanced electrochemiluminescence lateral flow immunoassay sensor for accurate sample-to-answer detection of luteinizing hormone
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2024.342646 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Kaifa Xue und 5 weiteren Autor:innen. Beteiligte Einrichtung: MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631…. Hauptthemen laut MEDLINE: Luteinizing Hormone, Electrochemical Techniques, Luminescent Measurements. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND: Colorimetric lateral flow immunoassay (LFIA) is a widely used point-of-care testing (POCT) technology, while it has entered a bottleneck period because of low detection sensitivity, expensive preparation materials, and incapable quantitative detection. Therefore, it is necessary to develop a novel POCT method that is ultrasensitive, simple, portable, and capable of accurately detecting biomarkers in biofluids daily, particularly for pregnancy preparation and early screening of diseases. RESULT: In this work, a novel dry chemistry-based self-enhanced electrochemiluminescence (DC-SE-ECL) LFIA sensor is introduced for accurate POCT of luteinizing hormone (LH). The proposed DC-SE-ECL immunosensor significantly improves the detection sensitivity through the Poly-l-Lysine (PLL)-based SE-ECL probe and cathode modification of closed bipolar electrode (C-BPE). Additionally, a new type of C-BPE configuration is designed for easily performing the LFIA. And, two standalone absorbent pads are symmetrically arranged below the reporting channel of the electrode pad to decease useless residues on the detection pad, which further improves the detection performance. Under optimized conditions, the proposed LFIA sensor has a low limit of detection (9.274 μIU mL-1) and a wide linear dynamic range (0.01-100 mIU mL-1), together with good selectivity, repeatability and storage stability. SIGNIFICANCE: These results indicate that the proposed DC-SE-ECL method has the potential as a new tool for detecting biomarkers in clinical samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, Co…
- Guangzhou First People's Hospital Nansha Hospital, Guangzhou, 511457, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Xue, K., Cai, B., Yang, Y., He, A., Chen, Z., & Zhang, C. (2024). A dry chemistry-based self-enhanced electrochemiluminescence lateral flow immunoassay sensor for accurate sample-to-answer detection of luteinizing hormone. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342646
Vancouver
Xue K, Cai B, Yang Y, He A, Chen Z, Zhang C. A dry chemistry-based self-enhanced electrochemiluminescence lateral flow immunoassay sensor for accurate sample-to-answer detection of luteinizing hormone. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342646
BibTeX
@article{Xue2024,
author = {Xue, Kaifa and Cai, Bolin and Yang, Yang and He, An and Chen, Zhenyu and Zhang, Chunsun},
title = {A dry chemistry-based self-enhanced electrochemiluminescence lateral flow immunoassay sensor for accurate sample-to-answer detection of luteinizing hormone},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2024.342646}
}
EUVIMED