EUVIMEDEUVIMED entdecken
Evaluationsstudie

Closed bipolar electrode-based immunosensing platform with cascade signal amplification for single potential-triggered simultaneous electrochemiluminescence–electrochromic dual-mode detection

Yu-Ling Wang, Chen Chen, Jia-Yao Xu, Yu-Jie Jing, Bing Wang, Jing Zhang, Yan-Ming Liu, Jun-Tao Cao

Biosensors and Bioelectronics · 2026-11 · 312 · 119077

DOI: 10.1016/j.bios.2026.119077 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Yu-Ling Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang…. Hauptthemen laut MEDLINE: Biosensing Techniques, Prostate-Specific Antigen, Electrochemical Techniques. Die Arbeit nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sensitive and accurate detection of tumor markers is crucial for disease diagnosis, yet numerous challenges still exist due to limitations of single-mode assays. This work constructed a universal dual-mode sensing platform combining closed bipolar electrode (cBPE) and split-type immunoassay, which realized simultaneous electrochemiluminescence (ECL) and electrochromic detection of proteins upon a single potential stimulus. Specifically, on the cBPE, L012 served as the ECL emitter at the anode, while Prussian blue (PB) film at the cathode acted as the electrochromic sensing unit. Applying a single potential stimulus could trigger simultaneous ECL emission and the color change from blue PB to white Prussian white. By virtue of MgO2@GOx-Ab2 signal probes as bioprobe, a split-type immunoassay was developed for prostate-specific antigen (PSA) detection. The target-induced production of H2O2 from cascade glucose oxidation and MgO2 hydrolysis greatly enhanced the anodic ECL signal and facilitated the cathodic PB reduction. Consequently, the strategy achieved the highly sensitive and visual dual-mode assay for PSA, yielding the limits of detection of 2.7 × 10-12 g/mL for ECL detection and 3.1 × 10-9 g/mL for electrochromic sensing, respectively. The study opened up an avenue for developing simultaneous multi-mode sensing platforms toward more biomarkers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesProstate-Specific AntigenElectrochemical TechniquesLuminescent MeasurementsElectrodesHumansImmunoassayLimit of DetectionHydrogen PeroxideEquipment Design

Stichwörter der Autor:innen

Closed bipolar electrodeDual-mode simultaneous analysisElectrochemiluminescenceElectrochromicsSingle potential stimulus

Substanzen

Prostate-Specific AntigenHydrogen Peroxide

Autor:innen und Institutionen

  • College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang, 464000, China.
  • Xinyang Central Hospital, Xinyang, 464000, China.
  • College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang, 464000, China. Electronic address: jtcao11@163.com.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Wang, Y. L., Chen, C., Xu, J. Y., Jing, Y. J., Wang, B., Zhang, J., Liu, Y. M., & Cao, J. T. (2026). Closed bipolar electrode-based immunosensing platform with cascade signal amplification for single potential-triggered simultaneous electrochemiluminescence–electrochromic dual-mode detection. Biosensors and Bioelectronics, 312, 119077. https://doi.org/10.1016/j.bios.2026.119077

Vancouver

Wang YL, Chen C, Xu JY, Jing YJ, Wang B, Zhang J, et al. Closed bipolar electrode-based immunosensing platform with cascade signal amplification for single potential-triggered simultaneous electrochemiluminescence–electrochromic dual-mode detection. Biosensors and Bioelectronics. 2026;312:119077. doi:10.1016/j.bios.2026.119077

BibTeX
@article{Wang2026,
  author = {Wang, Yu-Ling and Chen, Chen and Xu, Jia-Yao and Jing, Yu-Jie and Wang, Bing and Zhang, Jing and Liu, Yan-Ming and Cao, Jun-Tao},
  title = {Closed bipolar electrode-based immunosensing platform with cascade signal amplification for single potential-triggered simultaneous electrochemiluminescence–electrochromic dual-mode detection},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {312},
  pages = {119077},
  doi = {10.1016/j.bios.2026.119077}
}
Kostenlos starten →