EUVIMEDEUVIMED entdecken
Crossref

Development of a highly sensitive aptamer-based electrochemical sensor for detecting saxitoxin based on K3Fe(CN)6 regulated silver nanoparticles

Wei Zeng, Xuemei Tang, Ting Wu, Bingjun Han, Long Wu

Analytica Chimica Acta · 2024-01 · 1287 · 342134

DOI: 10.1016/j.aca.2023.342134 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-01. Verfasst von Wei Zeng und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Food Science and Engineering, Key Laboratory of Tropical Fruits and Vegetables Quality and Safety for State Market Regulation, Hainan Unive…. Hauptthemen laut MEDLINE: Saxitoxin, Metal Nanoparticles. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Hainan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Saxitoxin (STX) is the most toxic marine toxin, which can pose several adverse effects on human health. High sensitivity, fast response, and low-cost detection of STX contamination are of significance to reducing the fishery and seafood industries' loss. Among the various types of biosensors, the electrochemical biosensors have been extensively studied in the detection of STX, but the electrode surface modification material is easy to fall off, resulting in unstable electrochemical signals and poor reproducibility. It is imperative to have a ratiometric electrochemical biosensor for STX. RESULTS: In this study, we developed a novel aptamer-based electrochemical sensor (AECs) for the sensitive detection of STX based on a K3Fe(CN)6 regulated silver nanoparticles (Ag NPs) modified with aptamer. The AECs was constructed by immobilizing aptamer on Ag NPs surfaces. Under optimized conditions, the AECs showed a linear response towards STX in the range from 0.04 to 0.15 μM with the regression equation of Y = -8.0 + 233.7 X (R2 = 0.9956). The limit of detection (LOD) was calculated to be 1 nM (based on 3 N/S), which is significantly lower than the regulatory limits for STX in seafood. Moreover, the AECs showed excellent sensitivity, reproducibility and stability, as well as the detection in samples with acceptable recovery ranged from 71.2 % to 93.8 %, demonstrating its broad application prospects in detection of STX in seafood samples. SIGNIFICANCE: This work proposed an AECs to achieve sensitive detection of STX. A reaction system of K3Fe(CN)6 etched Ag NPs was introduced and used as the signal source to avoid the instability of the electrochemical signal, which can produce a ratiometric electrochemical signal output mode, improving the stability and sensitivity of electrochemical detection of STX.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SaxitoxinMetal NanoparticlesHumansSilverReproducibility of ResultsMarine ToxinsOligonucleotides

Stichwörter der Autor:innen

AptasensorEtching reactionFood safetyMarine biotoxinRatiometric detection

Substanzen

SaxitoxinSilverMarine ToxinsOligonucleotides

Autor:innen und Institutionen

  • School of Food Science and Engineering, Key Laboratory of Tropical Fruits and Vegetables Quality and Safety for State Market Regulation, Hainan University, Haikou, 570228, China.
  • Hainan Provincial Key Laboratory of Quality and Safety for Tropical Fruits and Vegetables, Analysis and Test Center, Chinese Academy of Tropical Agricultural Sciences, Haikou, 571101, China.
  • School of Food Science and Engineering, Key Laboratory of Tropical Fruits and Vegetables Quality and Safety for State Market Regulation, Hainan University, Haikou, 570228, China. Electronic address: longquan.good@163.co…

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Hainan Province

Zitieren

APA

Zeng, W., Tang, X., Wu, T., Han, B., & Wu, L. (2024). Development of a highly sensitive aptamer-based electrochemical sensor for detecting saxitoxin based on K3Fe(CN)6 regulated silver nanoparticles. Analytica Chimica Acta, 1287, 342134. https://doi.org/10.1016/j.aca.2023.342134

Vancouver

Zeng W, Tang X, Wu T, Han B, Wu L. Development of a highly sensitive aptamer-based electrochemical sensor for detecting saxitoxin based on K3Fe(CN)6 regulated silver nanoparticles. Analytica Chimica Acta. 2024;1287:342134. doi:10.1016/j.aca.2023.342134

BibTeX
@article{Zeng2024,
  author = {Zeng, Wei and Tang, Xuemei and Wu, Ting and Han, Bingjun and Wu, Long},
  title = {Development of a highly sensitive aptamer-based electrochemical sensor for detecting saxitoxin based on K3Fe(CN)6 regulated silver nanoparticles},
  journal = {Analytica Chimica Acta},
  year = {2024},
  volume = {1287},
  pages = {342134},
  doi = {10.1016/j.aca.2023.342134}
}
Kostenlos starten →