An anti-fouling wearable molecular imprinting sensor based on semi-interpenetrating network hydrogel for the detection of tryptophan in sweat
Analytica Chimica Acta · 2023-12 · 1283 · 341948
DOI: 10.1016/j.aca.2023.341948 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2023-12. Verfasst von Zhenying Xu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingda…. Hauptthemen laut MEDLINE: Biofouling, Molecular Imprinting, Wearable Electronic Devices. Die Arbeit wurde bisher 65-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
The challenge of heavy biofouling in complex sweat environments limits the potential of electrochemical sweat sensors for noninvasive physiological assessment. In this study, a novel semi-interpenetrating hydrogel of PSBMA/PEDOT:PSS was engineered by interlacing PEDOT:PSS conductive polymer with zwitterionic PSBMA network. This versatile hydrogel served as the foundation for developing an anti-fouling wearable molecular imprinting sensor capable of sensitive and robust detection of tryptophan (Trp) in complex sweat. The incorporation of PEDOT:PSS conductive polymer into the semi-interpenetrating hydrogel introduced diverse physical crosslinks, including hydrogen bonding, electrostatic interactions, and chain entanglement. This incorporation considerably boosted the hydrogel's mechanical robustness and imparted commendable self-healing property. At the same time, the synergistic coupling between the well-balanced charge of the zwitterionic network and the high conductivity of the PEDOT:PSS polymer facilitated efficient charge transfer. The formation of the desired molecular imprinting membrane of semi-interpenetrating hydrogel was triggered by self-polymerization of dopamine (DA) in the presence of Trp. The designed biosensor demonstrated good sensitivity, selectivity and stability in detecting the target Trp. Notably, it also exhibited exceptional anti-fouling abilities, allowing for accurate Trp detection in complex real sweat samples, yielding results comparable to commercial enzyme-linked immunoassay (ELISA).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China.
- School of Municipal and Environmental Engineering, Shandong Jianzhu University, Jinan, 250101, China.
- Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China. Electronic address: qiaoxiujuan2021@163.com.
- Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China. Electronic address: gcfan@qust.edu.cn.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Xu, Z., Liu, Y., Lv, M., Qiao, X., Fan, G. C., & Luo, X. (2023). An anti-fouling wearable molecular imprinting sensor based on semi-interpenetrating network hydrogel for the detection of tryptophan in sweat. Analytica Chimica Acta, 1283, 341948. https://doi.org/10.1016/j.aca.2023.341948
Vancouver
Xu Z, Liu Y, Lv M, Qiao X, Fan GC, Luo X. An anti-fouling wearable molecular imprinting sensor based on semi-interpenetrating network hydrogel for the detection of tryptophan in sweat. Analytica Chimica Acta. 2023;1283:341948. doi:10.1016/j.aca.2023.341948
BibTeX
@article{Xu2023,
author = {Xu, Zhenying and Liu, Yuanyuan and Lv, Mingrui and Qiao, Xiujuan and Fan, Gao-Chao and Luo, Xiliang},
title = {An anti-fouling wearable molecular imprinting sensor based on semi-interpenetrating network hydrogel for the detection of tryptophan in sweat},
journal = {Analytica Chimica Acta},
year = {2023},
volume = {1283},
pages = {341948},
doi = {10.1016/j.aca.2023.341948}
}
EUVIMED